Quantitative evaluation of lumbar intervertebral disc degeneration: a comparison of ultrashort time-to-echo T2* with T1rho relaxometry
Acta Radiologica · 2025-02 · 66 (2) · 137-145
DOI: 10.1177/02841851241309234 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Acta Radiologica, online erschienen am 24.01.2025. Verfasst von Li-Lan Wu und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Zhongshan Hospital (Xiamen), Fudan University, Xiamen, PR China. Hauptthemen laut MEDLINE: Lumbar Vertebrae, Intervertebral Disc Degeneration, Magnetic Resonance Imaging. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 40 Literaturangaben.
Abstract (Originalsprache)
Background
Early detection of changes in lumbar intervertebral disc degeneration (IVDD) has great clinical significance. T1rho and UTE-T2* relaxometry are capable of providing information about biochemical changes in IVDD. However, they have not been previously analyzed and compared directly in the same patients.
Purpose
To assess and compare the potential of T1rho and UTE-T2* in the diagnosis of early IVDD in vivo. Material and Methods The UTE-T2* and T1rho values of 389 lumbar discs (L1/2–L5/S1) in 78 individuals were measured in three segmented disc regions. The lumbar intervertebral disc was graded using the 5-level Pfirrmann grading system and divided into three categories. Statistical analysis was performed on the regional differences of UTE-T2* and T1rho relaxometry and correlation with IVDD.
Results
Both UTE-T2* and T1rho values were negatively correlated with Pfirrmann grade ( P < 0.001). They showed strong correlations with Pfirrmann grade in NP (r = −0.725 and −0.743, respectively; P < 0.001). Diagnostic accuracy of detecting early IVDD was better with T1rho than UTE-T2* value in AAF and NP, with areas under the curve (AUCs) of 0.834–0.934 (both P < 0.05). For advanced lumbar IVDD, UTE-T2* value showed significantly higher diagnostic accuracy than T1rho in all segments with AUCs in the range of 0.743–0.893 ( P < 0.05).
Conclusion
UTE-T2* relaxometry provided another promising magnetic resonance imaging sequence for quantitatively evaluating lumbar IVDD, especially for detection of the advanced stage of IVDD. In addition, the T1rho value is superior to UTE-T2* in detecting early lumbar IVDD.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Zhongshan Hospital (Xiamen), Fudan University, Xiamen, PR China.
- Xiamen Municipal Clinical Research Center for Medical Imaging, Xiamen, PR China.
- Department of Radiology, Zhongshan Hospital, Fudan University, shanghai, PR China.
- Shanghai Institute of Medical Imaging, shanghai, PR China.
ORCID-Profile: Li-Lan Wu, Jian-Jun Zhou
Zitieren
APA
Wu, L. L., Huang, S. F., Zhu, L. H., Liu, H., & Zhou, J. J. (2025). Quantitative evaluation of lumbar intervertebral disc degeneration: a comparison of ultrashort time-to-echo T2* with T1rho relaxometry. Acta Radiologica, 66(2), 137-145. https://doi.org/10.1177/02841851241309234
Vancouver
Wu LL, Huang SF, Zhu LH, Liu H, Zhou JJ. Quantitative evaluation of lumbar intervertebral disc degeneration: a comparison of ultrashort time-to-echo T2* with T1rho relaxometry. Acta Radiologica. 2025;66(2):137-145. doi:10.1177/02841851241309234
BibTeX
@article{Wu2025,
author = {Wu, Li-Lan and Huang, Shun-Fa and Zhu, Liu-Hong and Liu, Hao and Zhou, Jian-Jun},
title = {Quantitative evaluation of lumbar intervertebral disc degeneration: a comparison of ultrashort time-to-echo T2* with T1rho relaxometry},
journal = {Acta Radiologica},
year = {2025},
volume = {66},
number = {2},
pages = {137--145},
doi = {10.1177/02841851241309234}
}
EUVIMED