Segmentation-assisted fetal head descent measurement in intrapartum transperineal ultrasound

Jing Qiu, Shuqing Li, Daozhi Qian, Bentao Jiang, Linlin Song, Dongren Liu, Zhiyuan Yang

Frontiers in Medicine · 18.11.2026 · 13

DOI: 10.3389/fmed.2026.1921165 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Medicine, online erschienen am 18.11.2026. Verfasst von Jing Qiu und 6 weiteren Autor:innen. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

We evaluated whether segmentation of the pubic symphysis and fetal head supports reproducible Angle of Progression (AoP) and Head-Symphysis Distance (HSD) measurement in intrapartum transperineal ultrasound.

Methods

The PSFHS dataset was partitioned into 951 training, 136 validation, and 271 test images, with exact-image hashes grouped within splits. Nine segmentation architectures were compared during development, and the selected UNet++ workflow was finalized before test evaluation. For each image, AoP and HSD values from three independently trained models were averaged and compared with the arithmetic mean of three senior physicians' measurements.

Results

AoP mean absolute error was 5.4293 degrees (95% CI, 4.8579-6.0505), and HSD mean absolute error was 2.9904 pixels (95% CI, 2.5915-3.4285). Individual-model MAEs ranged from 5.7808 to 5.9612 degrees for AoP and from 3.1931 to 3.3237 pixels for HSD. Foreground Dice was 0.9449 ± 0.0011 across training runs, with no geometric measurement failures on the test images. A validation ablation showed that a small gain in segmentation overlap could accompany larger measurement errors.

Discussion

These results provide internal technical validation of the segmentation-to-measurement pathway against a physician mean reference. HSD remains in pixels, and patient-level independence could not be verified. External validation, reliable physical calibration, and prospective evaluation are needed to establish the workflow's usefulness in clinician-led intrapartum assessment.

Zitieren

APA

Qiu, J., Li, S., Qian, D., Jiang, B., Song, L., Liu, D., & Yang, Z. (2026). Segmentation-assisted fetal head descent measurement in intrapartum transperineal ultrasound. Frontiers in Medicine, 13. https://doi.org/10.3389/fmed.2026.1921165

Vancouver

Qiu J, Li S, Qian D, Jiang B, Song L, Liu D, et al. Segmentation-assisted fetal head descent measurement in intrapartum transperineal ultrasound. Frontiers in Medicine. 2026;13. doi:10.3389/fmed.2026.1921165

BibTeX
@article{Qiu2026,
  author = {Qiu, Jing and Li, Shuqing and Qian, Daozhi and Jiang, Bentao and Song, Linlin and Liu, Dongren and Yang, Zhiyuan},
  title = {Segmentation-assisted fetal head descent measurement in intrapartum transperineal ultrasound},
  journal = {Frontiers in Medicine},
  year = {2026},
  volume = {13},
  doi = {10.3389/fmed.2026.1921165}
}
Kostenlos starten →