Transperineal Ultrasound Assessment of Fetal Head Descent and Successful Manual Rotation in Women Undergoing Labor With Neuraxial Analgesia
Journal of Obstetrics and Gynaecology Research · 2026-11 · 52 (11)
DOI: 10.1111/jog.70558 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Obstetrics and Gynaecology Research, online erschienen am 13.11.2026. Verfasst von Yusuke Suzuki und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Obstetrics and Gynecology, Showa Medical University School of Medicine, Tokyo, Japan. Hauptthemen laut MEDLINE: Ultrasonography, Prenatal, Labor Presentation, Version, Fetal, Analgesia, Obstetrical. Die Arbeit nennt 17 Literaturangaben.
Abstract (Originalsprache)
Aim
Manual rotation is commonly used to correct fetal head malrotation during labor. This study assessed the effectiveness of manual rotation under neuraxial analgesia and evaluated whether transperineal ultrasound (TUS)‐derived parameters were associated with procedural success and could provide additional information when considering manual rotation.
Methods
We conducted a retrospective cohort study of 59 women with fetal rotational abnormalities during labor under neuraxial analgesia at a tertiary care center. Rotational abnormalities were defined as occiput posterior or occiput transverse positions with a midline angle (MLA) ≥ 45°, assessed 1 h after full cervical dilation. Manual rotation success was defined as correction to an MLA < 45°. Delivery, maternal, neonatal, and TUS‐derived parameters were compared between successful and unsuccessful cases.
Results
Manual rotation was successful in 44 of 59 cases (74.5%). The vaginal delivery rate was significantly higher in the successful group than in the unsuccessful group (90.9% vs. 46.7%, p < 0.001). No significant differences were noted in maternal or neonatal outcomes. Among TUS parameters, only the TUS‐station was significantly associated with procedural success. Receiver operating characteristic analysis identified a cutoff of 14.3 mm, above which the likelihood of successful rotation was 95.8%. In exploratory logistic regression models, TUS‐station remained associated with successful manual rotation after adjustment for clinically relevant covariates.
Conclusions
Manual rotation performed under neuraxial analgesia was associated with a high‐procedural success rate. A TUS‐station ≥ 14.3 mm was associated with a high likelihood of successful manual rotation and may provide complementary information when considering the procedure, although further validation is required.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Obstetrics and Gynecology, Showa Medical University School of Medicine, Tokyo, Japan.
ORCID-Profile: Yusuke Suzuki, Hiroko Takita, Ryu Matsuoka, Shin Hashiramoto, Yuki Mukai, Takeshi Nakamura, Akihiko Sekizawa
Zitieren
APA
Suzuki, Y., Takita, H., Matsuoka, R., Hashiramoto, S., Mukai, Y., Nakamura, T., & Sekizawa, A. (2026). Transperineal Ultrasound Assessment of Fetal Head Descent and Successful Manual Rotation in Women Undergoing Labor With Neuraxial Analgesia. Journal of Obstetrics and Gynaecology Research, 52(11). https://doi.org/10.1111/jog.70558
Vancouver
Suzuki Y, Takita H, Matsuoka R, Hashiramoto S, Mukai Y, Nakamura T, et al. Transperineal Ultrasound Assessment of Fetal Head Descent and Successful Manual Rotation in Women Undergoing Labor With Neuraxial Analgesia. Journal of Obstetrics and Gynaecology Research. 2026;52(11). doi:10.1111/jog.70558
BibTeX
@article{Suzuki2026,
author = {Suzuki, Yusuke and Takita, Hiroko and Matsuoka, Ryu and Hashiramoto, Shin and Mukai, Yuki and Nakamura, Takeshi and Sekizawa, Akihiko},
title = {Transperineal Ultrasound Assessment of Fetal Head Descent and Successful Manual Rotation in Women Undergoing Labor With Neuraxial Analgesia},
journal = {Journal of Obstetrics and Gynaecology Research},
year = {2026},
volume = {52},
number = {11},
doi = {10.1111/jog.70558}
}
EUVIMED