EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Critical evaluation of commonly used methods to determine the concordance between sonography and magnetic resonance imaging: A comparative study

Konstantin Warneke, Michael Keiner, Lars Hubertus Lohmann, Anna Brinkmann, Andreas Hein, Stephan Schiemann, Klaus Wirth

Frontiers in Imaging · 2022

DOI: 10.3389/fimag.2022.1039721 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Imaging, 2022. Verfasst von Konstantin Warneke und 6 weiteren Autor:innen. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 87 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Deutsche Forschungsgemeinschaft.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

An increasing number of studies investigate the influence of training interventions on muscle thickness (MT) by using ultrasonography. Ultrasonography is stated as a reliable and valid tool to examine muscle morphology. Researches investigating the effects of a training intervention lasting a few weeks need a very precise measurement since increases in MT can be assumed as small. Therefore, the aim of the present work was to investigate the concordance between MT via sonography and muscle cross-sectional area (MCSA) determined via MRI imaging (gold standard) in the calf muscle.

Methods

Reliability of sonography measurement and the concordance correlation coefficient, the mean error (ME), mean absolute error (MAE) and the mean absolute percentage error (MAPE) between sonography and MRI were determined.

Results

Results show intraclass correlation coefficients (ICC) of 0.88–0.95 and MAPE of 4.63–8.57% . Concordance between MT and MCSA was examined showing ρ = 0.69–0.75 for the medial head and 0.39–0.51 c for the lateral head of the gastrocnemius. A MAPE of 15.88–19.94% between measurements were determined. Based on this, assuming small increases in MT due to training interventions, even with an ICC of 0.95 , MAPE shows a high error between two investigators and therefore limited objectivity.

Discussion

The high MAPE of 15.88–19.94% as well as CCC of ρ c = 0.39–0.75 exhibit that there are significant differences between MRI and sonography. Therefore, data from short term interventions using sonography to detect changes in the MT should be handled with caution.

Förderung

  • Deutsche Forschungsgemeinschaft

Zitieren

APA

Warneke, K., Keiner, M., Lohmann, L. H., Brinkmann, A., Hein, A., Schiemann, S., & Wirth, K. (2022). Critical evaluation of commonly used methods to determine the concordance between sonography and magnetic resonance imaging: A comparative study. Frontiers in Imaging. https://doi.org/10.3389/fimag.2022.1039721

Vancouver

Warneke K, Keiner M, Lohmann LH, Brinkmann A, Hein A, Schiemann S, et al. Critical evaluation of commonly used methods to determine the concordance between sonography and magnetic resonance imaging: A comparative study. Frontiers in Imaging. 2022. doi:10.3389/fimag.2022.1039721

BibTeX
@article{Warneke2022,
  author = {Warneke, Konstantin and Keiner, Michael and Lohmann, Lars Hubertus and Brinkmann, Anna and Hein, Andreas and Schiemann, Stephan and Wirth, Klaus},
  title = {Critical evaluation of commonly used methods to determine the concordance between sonography and magnetic resonance imaging: A comparative study},
  journal = {Frontiers in Imaging},
  year = {2022},
  doi = {10.3389/fimag.2022.1039721}
}
Kostenlos starten →