EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access

Which sequence should be used in the thorax magnetic resonance imaging of COVID-19: a comparative study

Ayşe Şule Ateş iD, Burak Yağdiran iD, Onur Taydaş iD, Ömer Faruk Ateş iD

Turkish Journal of Medical Sciences · 26.10.2023 · 53 (5) · 1214-1223

DOI: 10.55730/1300-0144.5687 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Turkish Journal of Medical Sciences, online erschienen am 26.10.2023. Verfasst von Ayşe Şule Ateş und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chest Diseases, Faculty of Medicine, Sakarya University, Sakarya, Turkiye. Hauptthemen laut MEDLINE: COVID-19, Magnetic Resonance Imaging, SARS-CoV-2. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and aim: To evaluate and compare magnetic resonance imaging (MRI) sequences that could potentially be used in the diagnosis of coronavirus disease 2019 (COVID-19). Materials and methods: Included in the study were 42 patient who underwent thorax computed tomography (CT) for COVID-19 pneumonia and thorax MRI for any reason within 24 h after CT. The T2-weighted fast spin echo periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) (T2W-FSE-P), fast imaging employing steady-state acquisition, T2 fat-saturated FSE, axial T1 liver acquisition with volume acceleration (LAVA) and single-shot FSE images were compared in terms of their ability to show COVID-19 findings.

Results

The mean age of the patients was 47.2 ± 24 years. Of the patients, 22 were male (52.4%) and 20 (47.6%) were female. The interobserver intraclass coefficient (ICC) for the image quality score was the highest in the T2W-FSE-P sequence and lowest in the T1 LAVA sequence. All of the lesion-based evaluations of the interobserver agreement were statistically significant, with the kappa value varying between 0.798 and 0.998.

Conclusion

All 5 sequences evaluated in the study were successful in showing the parenchymal findings of COVID-19. Since the T2WFSE-P sequence had the best scores in both interobserver agreement and ICC for the image quality score, it was considered that it can be included in thorax MRI examinations to assist the diagnosis of COVID-19.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

COVID-19Magnetic Resonance ImagingSARS-CoV-2HumansMaleFemaleMiddle AgedAdultThoraxTomography, X-Ray ComputedAgedLung

Stichwörter der Autor:innen

COVID-19interobserver agreementinterobserver intraclass coefficientsmagnetic resonance imagingsequence

Autor:innen und Institutionen

  • Department of Chest Diseases, Faculty of Medicine, Sakarya University, Sakarya, Turkiye.
  • Department of Radiology, Faculty of Medicine, Başkent University, Ankara, Turkiye.
  • Department of Radiology, Faculty of Medicine, Sakarya University, Sakarya, Turkiye.

ORCID-Profile: Ayşe Şule Ateş, Burak Yağdiran, Onur Taydaş, Ömer Faruk Ateş

Zitieren

APA

Ateş, A. Ş., Yağdiran, B., Taydaş, O., & Ateş, Ö. F. (2023). Which sequence should be used in the thorax magnetic resonance imaging of COVID-19: a comparative study. Turkish Journal of Medical Sciences, 53(5), 1214-1223. https://doi.org/10.55730/1300-0144.5687

Vancouver

Ateş AŞ, Yağdiran B, Taydaş O, Ateş ÖF. Which sequence should be used in the thorax magnetic resonance imaging of COVID-19: a comparative study. Turkish Journal of Medical Sciences. 2023;53(5):1214-1223. doi:10.55730/1300-0144.5687

BibTeX
@article{Ate2023,
  author = {Ateş, Ayşe Şule and Yağdiran, Burak and Taydaş, Onur and Ateş, Ömer Faruk},
  title = {Which sequence should be used in the thorax magnetic resonance imaging of COVID-19: a comparative study},
  journal = {Turkish Journal of Medical Sciences},
  year = {2023},
  volume = {53},
  number = {5},
  pages = {1214--1223},
  doi = {10.55730/1300-0144.5687}
}
Kostenlos starten →