Comparison of smartwatch-derived energy expenditure estimation during outdoor activities
Frontiers in Digital Health · 24.08.2026 · 8
DOI: 10.3389/fdgth.2026.1926837 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Digital Health, online erschienen am 24.08.2026. Verfasst von Haedo Cho und 2 weiteren Autor:innen. Beteiligte Einrichtung: John A. Paulson School of Engineering and Applied Sciences, Harvard University, Boston, MA, United States. Die Arbeit nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Harvard University.
Abstract (Originalsprache)
Smartwatches are commonly used to estimate energy expenditure, but studies have reported errors of 25% to 70%, possibly due to factors such as activity type, use case, and sensor data. We compared three readily available configurations for estimating energy expenditure during outdoor walking and running: a smartwatch operated in its activity-specific mode that incorporated GPS, IMU, and heart rate data; a smartwatch operated in its generic, non-activity-specific mode that incorporated IMU and heart rate data; and a pre-defined heart rate model. Thirty adults (17 men, 13 women; 34 ± 14 years) completed outdoor activities while wearing a portable respirometry system and both smartwatches. Participants performed self-paced walking and running conditions, and followed ecologically relevant audio prompts to elicit real-world walking. Cumulative energy expenditure from each method was compared with ground-truth respirometry. The activity-specific smartwatch achieved 13% error during outdoor walking with 2.2–2.8 times lower error than the generic smartwatch and heart rate model, which could be attributed to its activity-specific algorithm, GPS availability, hardware, or a combination of these factors. The heart rate model yielded a lower error than both the activity-specific and non-activity-specific smartwatches during outdoor running in this cohort. This study reflects practical differences between commercially available setups as device, sensor suite, and proprietary algorithms differ across these tools. Estimates from non-activity-specific smartwatches, such as the Fitbit Charge 4 tested here, should be interpreted cautiously by researchers, clinicians, and users when monitoring physical activity.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- John A. Paulson School of Engineering and Applied Sciences, Harvard University, Boston, MA, United States.
- Kempner Institute for the Study of Artificial and Natural Intelligence, Harvard University, Boston, MA, United States.
Förderung
- Harvard University
Zitieren
APA
Cho, H., Campillo Rodriguez, C., & Slade, P. (2026). Comparison of smartwatch-derived energy expenditure estimation during outdoor activities. Frontiers in Digital Health, 8. https://doi.org/10.3389/fdgth.2026.1926837
Vancouver
Cho H, Campillo Rodriguez C, Slade P. Comparison of smartwatch-derived energy expenditure estimation during outdoor activities. Frontiers in Digital Health. 2026;8. doi:10.3389/fdgth.2026.1926837
BibTeX
@article{Cho2026,
author = {Cho, Haedo and Campillo Rodriguez, Chelsey and Slade, Patrick},
title = {Comparison of smartwatch-derived energy expenditure estimation during outdoor activities},
journal = {Frontiers in Digital Health},
year = {2026},
volume = {8},
doi = {10.3389/fdgth.2026.1926837}
}
EUVIMED