EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Higher very short-term blood pressure variability is associated with lower atrial fibrillation recurrence after catheter ablation

Sadahiro Murota, Minoru Nodera, Naoto Ohashi, Ryo Ogawara, Yu Sato, Tetsuro Yokokawa, Tomofumi Misaka, Shinya Yamada, Takashi Kaneshiro, Masayoshi Oikawa, Akiomi Yoshihisa, Yasuchika Takeishi

Frontiers in Cardiovascular Medicine · 16.03.2026 · 13

DOI: 10.3389/fcvm.2026.1779540 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Cardiovascular Medicine, online erschienen am 16.03.2026. Verfasst von Sadahiro Murota und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Medicine, Fukushima Medical University, Fukushima, Japan. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Blood pressure variability (BPV) is a cardiovascular risk marker independent of mean blood pressure. Prior studies have suggested potential associations between BPV and atrial fibrillation (AF) recurrence, but the relevance of very short-term, beat-to-beat BPV remains uncertain.

Methods

In this single-center retrospective cohort study, we enrolled 153 consecutive patients undergoing first-time AF ablation who underwent pre-procedural overnight polygraphy with simultaneous pulse transit time-based beat-to-beat blood pressure monitoring. Very short-term BPV was quantified as the standard deviation (SD) of nighttime beat-to-beat systolic, diastolic, and mean blood pressure (SBP, DBP, and MBP); patients were dichotomized at the median. The primary endpoint was the first recurrence of AF lasting ≥ 30s beyond a 3-month blanking period during 12 months of follow-up.

Results

During follow-up, AF recurrence occurred in 15 patients (9.8%). Kaplan–Meier curves showed significantly lower recurrence rates in the higher BPV groups (SD of SBP: P = 0.015; SD of DBP: P = 0.002; and SD of MBP: P = 0.003). In univariable Cox proportional hazards models, higher BPV was associated with lower recurrence risk (SD of SBP: hazard ratio 0.519, 95% confidence interval 0.311–0.865; SD of DBP: hazard ratio 0.258, 95% confidence interval 0.101–0.664; and SD of MBP: hazard ratio 0.251, 95% confidence interval 0.099–0.638).

Conclusion

Higher nighttime very short-term BPV was associated with lower AF recurrence after first-time ablation. Pulse transit time-based cuffless monitoring may provide a practical method for preprocedural risk stratification; confirmation via multicenter studies is warranted.

Schlagwörter

Stichwörter der Autor:innen

atrial fibrillationbaroreflex sensitivityblood pressure variabilitycatheter ablationpulse transit time

Autor:innen und Institutionen

  • Department of Cardiovascular Medicine, Fukushima Medical University, Fukushima, Japan.

Zitieren

APA

Murota, S., Nodera, M., Ohashi, N., Ogawara, R., Sato, Y., Yokokawa, T., Misaka, T., Yamada, S., Kaneshiro, T., Oikawa, M., Yoshihisa, A., & Takeishi, Y. (2026). Higher very short-term blood pressure variability is associated with lower atrial fibrillation recurrence after catheter ablation. Frontiers in Cardiovascular Medicine, 13. https://doi.org/10.3389/fcvm.2026.1779540

Vancouver

Murota S, Nodera M, Ohashi N, Ogawara R, Sato Y, Yokokawa T, et al. Higher very short-term blood pressure variability is associated with lower atrial fibrillation recurrence after catheter ablation. Frontiers in Cardiovascular Medicine. 2026;13. doi:10.3389/fcvm.2026.1779540

BibTeX
@article{Murota2026,
  author = {Murota, Sadahiro and Nodera, Minoru and Ohashi, Naoto and Ogawara, Ryo and Sato, Yu and Yokokawa, Tetsuro and Misaka, Tomofumi and Yamada, Shinya and Kaneshiro, Takashi and Oikawa, Masayoshi and Yoshihisa, Akiomi and Takeishi, Yasuchika},
  title = {Higher very short-term blood pressure variability is associated with lower atrial fibrillation recurrence after catheter ablation},
  journal = {Frontiers in Cardiovascular Medicine},
  year = {2026},
  volume = {13},
  doi = {10.3389/fcvm.2026.1779540}
}
Kostenlos starten →