Repeat catheter ablation after very late recurrence of atrial fibrillation after pulmonary vein isolation
Europace · 02.05.2024 · 26 (5)
DOI: 10.1093/europace/euae096 ↗Kurz gefasst
Fachartikel in der Zeitschrift Europace, online erschienen am 12.04.2024. Verfasst von Niklas Stauffer und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, University Hospital Basel, Petersgraben 4, 4031 Basel, Switzerland. Hauptthemen laut MEDLINE: Atrial Fibrillation, Catheter Ablation, Pulmonary Veins, Recurrence. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Aims
Atrial fibrillation (AF) recurs in about one-third of patients after catheter ablation (CA), mostly in the first year. Little is known about the electrophysiological findings and the effect of re-ablation in very late AF recurrences (VLR) after more than 1 year. The aim of this study was to determine the characteristics and outcomes of the first repeat CA after VLR of AF after index CA. Methods and results We analysed patients from a prospective Swiss registry that underwent a first repeat ablation procedure. Patients were stratified depending on the time to recurrence after index procedure: early recurrence (ER) for recurrences within the first year and late recurrence (LR) if the recurrence was later. The primary endpoint was freedom from AF in the first year after repeat ablation. Out of 1864 patients included in the registry, 426 patients undergoing a repeat ablation were included in the analysis (28% female, age 63 ± 9.8 years, 46% persistent AF). Two hundred and ninety-one patients (68%) were stratified in the ER group and 135 patients (32%) in the LR group. Pulmonary vein reconnections were a common finding in both groups, with 93% in the ER group compared to 86% in the LR group (P = 0.052). In the LR group, 40 of 135 patients (30%) had a recurrence of AF compared to 90 of 291 patients (31%) in the ER group (log-rank P = 0.72).
Conclusion
There was no association between the time to recurrence of AF after initial CA and the characteristics and outcomes of the repeat procedure.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, University Hospital Basel, Petersgraben 4, 4031 Basel, Switzerland.
- Cardiovascular Research Institute Basel, University Hospital Basel, Spitalstrasse 2, 4056 Basel, Switzerland.
ORCID-Profile: Niklas Stauffer, Sven Knecht, Patrick Badertscher, Philipp Krisai, Elisa Hennings, Teodor Serban, Gian Voellmin, Stefan Osswald, Christian Sticherling, Michael Kühne
Zitieren
APA
Stauffer, N., Knecht, S., Badertscher, P., Krisai, P., Hennings, E., Serban, T., Voellmin, G., Osswald, S., Sticherling, C., & Kühne, M. (2024). Repeat catheter ablation after very late recurrence of atrial fibrillation after pulmonary vein isolation. Europace, 26(5). https://doi.org/10.1093/europace/euae096
Vancouver
Stauffer N, Knecht S, Badertscher P, Krisai P, Hennings E, Serban T, et al. Repeat catheter ablation after very late recurrence of atrial fibrillation after pulmonary vein isolation. Europace. 2024;26(5). doi:10.1093/europace/euae096