Differential biomarker responses of hemolysis, inflammation, and myocardial injury after pulsed-field pulmonary vein isolation: balloon-in-basket vs. circular catheter systems

Jan-Per Wenzel, Raed Abdessadok, Charlotte Eitel, Sorin Popescu, Suzanne de Waha, Tanja Zeller, Karl-Heinz Kuck, Roland Richard Tilz, Sascha Hatahet

Frontiers in Cardiovascular Medicine · 29.05.2026 · 13

DOI: 10.3389/fcvm.2026.1774443 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Cardiovascular Medicine, online erschienen am 29.05.2026. Verfasst von Jan-Per Wenzel und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Rhythmology, Heart Center Lübeck, University Hospital Schleswig-Holstein, Lübeck, Germany. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Pulsed-field ablation (PFA) is a non-thermal energy source for pulmonary vein isolation (PVI). Data comparing the biological impact of different PFA technologies remain limited. This study assessed changes in biomarkers of hemolysis, inflammation, and biochemical myocardial injury using two PFA systems: a balloon-in-basket (BiB) and a circular catheter (PS).

Methods

This prospective, single-center, non-randomized study enrolled consecutive patients undergoing first-time PVI. leukocytes, C-reactive protein (CRP), platelets, lactate dehydrogenase (LDH), haptoglobin, total bilirubin, troponin T, creatine kinase (CK), myoglobin, creatinine, and estimated glomerular filtration rate (eGFR) were before and 16–18 h after ablation.

Results

Forty patients were included (BiB n = 20, PS n = 20). Baseline characteristics were comparable. Acute PVI was achieved in all cases. BiB required fewer applications (16 vs. 32, p < 0.001), more contrast (45 vs. 30 mL, p < 0.001), and had longer procedure and LA dwell times ( p < 0.001). Both systems caused significant increases in leukocytes, CRP, LDH, troponin, and CK without inter-group differences. Haptoglobin decreased significantly in both, more pronounced with PS (Δ −13 vs. −4 mg/dL, p = 0.090). Renal function remained stable overall, with one PS patient developing an acute kidney injury. In the BiB group, Δ-Hemoglobin correlated inversely with application number ( p = 0.046). In the PS group, Δ -Troponin and Δ -CK correlated positively ( p < 0.05).

Conclusion

Despite comparable overall biomarker responses, a numerically greater, non-significant haptoglobin decline and an isolated, likely multifactorial transient AKI in the PS group may suggest differences in biomarker responses, warranting further investigation in larger studies. However, the clinical relevance of these findings remains uncertain.

Schlagwörter

Stichwörter der Autor:innen

atrial fibrillationballon-in-basketcircular catheterhemolysisinflammationmyocardial injurypulmonary vein isolationpulsed-field ablation

Autor:innen und Institutionen

  • Department of Rhythmology, Heart Center Lübeck, University Hospital Schleswig-Holstein, Lübeck, Germany.
  • German Center for Cardiovascular Research (DZHK), Partner Site, Lübeck, Germany.
  • Institute for Cardiogenetics, University Hospital Schleswig-Holstein, Lübeck, Germany.

Zitieren

APA

Wenzel, J. P., Abdessadok, R., Eitel, C., Popescu, S., de Waha, S., Zeller, T., Kuck, K. H., Tilz, R. R., & Hatahet, S. (2026). Differential biomarker responses of hemolysis, inflammation, and myocardial injury after pulsed-field pulmonary vein isolation: balloon-in-basket vs. circular catheter systems. Frontiers in Cardiovascular Medicine, 13. https://doi.org/10.3389/fcvm.2026.1774443

Vancouver

Wenzel JP, Abdessadok R, Eitel C, Popescu S, de Waha S, Zeller T, et al. Differential biomarker responses of hemolysis, inflammation, and myocardial injury after pulsed-field pulmonary vein isolation: balloon-in-basket vs. circular catheter systems. Frontiers in Cardiovascular Medicine. 2026;13. doi:10.3389/fcvm.2026.1774443

BibTeX
@article{Wenzel2026,
  author = {Wenzel, Jan-Per and Abdessadok, Raed and Eitel, Charlotte and Popescu, Sorin and de Waha, Suzanne and Zeller, Tanja and Kuck, Karl-Heinz and Tilz, Roland Richard and Hatahet, Sascha},
  title = {Differential biomarker responses of hemolysis, inflammation, and myocardial injury after pulsed-field pulmonary vein isolation: balloon-in-basket vs. circular catheter systems},
  journal = {Frontiers in Cardiovascular Medicine},
  year = {2026},
  volume = {13},
  doi = {10.3389/fcvm.2026.1774443}
}
Kostenlos starten →