Inflammatory and Myocardial Biomarker Response Following Pulmonary Vein Isolation: Cryoballoon Versus Balloon‐in‐Basket Pulsed Field Ablation
Journal of Cardiovascular Electrophysiology · 2026
DOI: 10.1111/jce.70221 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2026. Verfasst von Jan-Per Wenzel und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Rhythmology, University Heart Center Lübeck, University Hospital Schleswig-Holstein, Lübeck, Germany. Hauptthemen laut MEDLINE: Cryosurgery, Atrial Fibrillation, Pulmonary Veins, Inflammation Mediators. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Cryoballoon ablation (CB) is a well‐established thermal technique for pulmonary vein isolation (PVI), while balloon‐in‐basket pulsed field ablation (BiB‐PFA) represents a novel non‐thermal alternative. Both single‐shot systems may trigger systemic inflammation and myocardial injury, yet direct comparisons are lacking. This study aimed to compare inflammatory and myocardial biomarker responses following first‐time PVI using CB or BiB‐PFA.
Methods
In this prospective, single‐center study, 100 patients undergoing PVI for symptomatic paroxysmal or persistent atrial fibrillation (AF) were enrolled (CB: n = 50; BiB‐PFA: n = 50). Venous blood samples were collected before and on the morning after ablation to assess leukocytes, C‐reactive protein (CRP), platelets, troponin T, creatine kinase (CK), myoglobin, creatinine, and estimated glomerular filtration rate. Baseline characteristics, procedural data, and acute success were analyzed.
Results
Patients in the CB group were older (74 vs. 65 years; p = 0.01) and had higher CHA₂DS₂‐VAcore (3.0 vs. 2.0; p = 0.009). Acute PVI was achieved in all cases CB was associated with greater increases in leukocytes (Δ2.5 vs. 1.1 × 10⁹/L; p = 0.05) and CRP (Δ5.8 vs. 3.4 mg/L; p = 0.02), whereas BiB‐PFA showed higher rises in CK (Δ217 vs. 103 U/L; p = 0.01) and troponin T (Δ1129 vs. 614.5 ng/L; p = 0.01). No significant correlation was found between energy delivery and biomarker changes.
Conclusion
CB and BiB‐PFA elicit distinct systemic responses. CB provoked stronger inflammatory activation, while BiB‐PFA caused greater myocardial biomarker release, suggesting energy‐ and device‐specific effects.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Rhythmology, University Heart Center Lübeck, University Hospital Schleswig-Holstein, Lübeck, Germany.
- German Center for Cardiovascular Research (DZHK), Partner Site Lübeck, Germany.
- Institute for Cardiogenetics, University Hospital Schleswig-Holstein, Lübeck, Germany.
ORCID-Profile: Julius Nikorowitsch
Zitieren
APA
Wenzel, J. P., Hatahet, S., Eitel, C., Abdessadok, R., Popescu, S., Nikorowitsch, J., de Waha, S., Zeller, T., Kuck, K. H., & Tilz, R. R. (2026). Inflammatory and Myocardial Biomarker Response Following Pulmonary Vein Isolation: Cryoballoon Versus Balloon‐in‐Basket Pulsed Field Ablation. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.70221
Vancouver
Wenzel JP, Hatahet S, Eitel C, Abdessadok R, Popescu S, Nikorowitsch J, et al. Inflammatory and Myocardial Biomarker Response Following Pulmonary Vein Isolation: Cryoballoon Versus Balloon‐in‐Basket Pulsed Field Ablation. Journal of Cardiovascular Electrophysiology. 2026. doi:10.1111/jce.70221
BibTeX
@article{Wenzel2026,
author = {Wenzel, Jan-Per and Hatahet, Sascha and Eitel, Charlotte and Abdessadok, Raed and Popescu, Sorin and Nikorowitsch, Julius and de Waha, Suzanne and Zeller, Tanja and Kuck, Karl-Heinz and Tilz, Roland Richard},
title = {Inflammatory and Myocardial Biomarker Response Following Pulmonary Vein Isolation: Cryoballoon Versus Balloon‐in‐Basket Pulsed Field Ablation},
journal = {Journal of Cardiovascular Electrophysiology},
year = {2026},
doi = {10.1111/jce.70221}
}