Assessment of the thoracic aorta after aortic root replacement and/or ascending aortic surgery using 3D relaxation-enhanced angiography without contrast and triggering
Frontiers in Cardiovascular Medicine · 12.03.2025 · 12
DOI: 10.3389/fcvm.2025.1532661 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Cardiovascular Medicine, online erschienen am 12.03.2025. Verfasst von Carsten Gietzen und 14 weiteren Autor:innen. Beteiligte Einrichtung: Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objective
Relaxation-Enhanced Angiography without Contrast and Triggering (REACT) is a novel 3D isotropic flow-independent non-contrast-enhanced MRA (non-CE-MRA) and has shown promising results in imaging of the thoracic aorta, primarily in patients without prior aortic surgery. The purpose of this study was to evaluate the performance of REACT after surgery of the aortic root and/or ascending aorta by performing an intraindividual comparison to CE-MRA. Material and methods This retrospective single center study included 58 MRI studies of 34 patients [mean age at first examination 45.64 ± 11.13 years, 31 (53.44%) female] after ascending aortic surgery. MRI was performed at 1.5T using REACT (ECG- and respiratory-triggering, Compressed SENSE factor 9, acquired spatial resolution 1.69 × 1.70 × 1.70 mm 3 ) and untriggered 3D CE-MRA. Independently, two radiologists measured maximum and minimum vessel diameters (inner-edge) and evaluated image quality and motion artifacts on 5-point scales (5 = excellent) for the following levels: mid-graft, distal anastomosis, ascending aorta, aortic arch, and descending aorta. Additionally, readers evaluated MRAs for the presence of aortic dissection (AD) and graded the quality of depiction as well as their diagnostic confidence using 5-point scales (5 = excellent).
Results
Vessel diameters were comparable between CE-MRA and REACT (total acquisition time: 05:42 ± 00:38 min) with good to excellent intersequence agreement (ICC = 0.86–0.96). At the distal anastomosis (minimum/maximum, p < .001/ p = .002) and at the ascending aorta (minimum/maximum, p = .002/ p = .06), CE-MRA yielded slightly larger diameters. Image quality for all levels combined was higher in REACT [median (IQR); 3.6 (3.2–3.93) vs. 3.9 (3.6–4.13), p = .002], with statistically significant differences at mid-graft [3.0 (2.5–3.63) vs. 4.0 (4.0–4.0), p < .001] and ascending aorta [3.25 (3.0–4.0) vs. 4.0 (3.5–4.0), p < .001]. Motion artifacts were more present in CE-MRA at all levels ( p < .001). Using CE-MRA as the standard of reference, readers detected all 25 cases of residual AD [Stanford type A: 21 (84.0%); Stanford type B: 4 (16.0%)] in REACT with equal quality of depiction [4.0 (3.0–4.5) vs. 4.0 (3.0–4.0), p = .41] and diagnostic confidence [4.0 (3.0–4.0) vs. 4.0 (3.0–4.0), p = .81) in both sequences.
Conclusions
This study indicates the feasibility of REACT for assessment of the thoracic aorta after ascending aortic surgery and expands its clinical use for gadolinium-free MRA to these patients.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.
- Department of Cardiac Surgery, Heart Center, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.
- Department of Cardiology, Heart Center, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.
- Department for Orthopedic and Trauma Surgery, University Hospital of Bonn, Bonn, Germany.
- Philips Healthcare Germany, Hamburg, Germany.
Zitieren
APA
Gietzen, C., Janssen, J. P., Tristram, J., Cagman, B., Kaya, K., Terzis, R., Gertz, R., Gietzen, T., Pennig, H., Bunck, A. C., Maintz, D., Persigehl, T., Mader, N., Weiss, K., & Pennig, L. (2025). Assessment of the thoracic aorta after aortic root replacement and/or ascending aortic surgery using 3D relaxation-enhanced angiography without contrast and triggering. Frontiers in Cardiovascular Medicine, 12. https://doi.org/10.3389/fcvm.2025.1532661
Vancouver
Gietzen C, Janssen JP, Tristram J, Cagman B, Kaya K, Terzis R, et al. Assessment of the thoracic aorta after aortic root replacement and/or ascending aortic surgery using 3D relaxation-enhanced angiography without contrast and triggering. Frontiers in Cardiovascular Medicine. 2025;12. doi:10.3389/fcvm.2025.1532661
BibTeX
@article{Gietzen2025,
author = {Gietzen, Carsten and Janssen, Jan Paul and Tristram, Juliana and Cagman, Burak and Kaya, Kenan and Terzis, Robert and Gertz, Roman and Gietzen, Thorsten and Pennig, Henry and Bunck, Alexander C and Maintz, David and Persigehl, Thorsten and Mader, Navid and Weiss, Kilian and Pennig, Lenhard},
title = {Assessment of the thoracic aorta after aortic root replacement and/or ascending aortic surgery using 3D relaxation-enhanced angiography without contrast and triggering},
journal = {Frontiers in Cardiovascular Medicine},
year = {2025},
volume = {12},
doi = {10.3389/fcvm.2025.1532661}
}
EUVIMED