A novel, rapid, ultrasensitive diagnosis platform for detecting Candida albicans using restriction endonuclease‐mediated real-time loop-mediated isothermal amplification
Frontiers in Cellular and Infection Microbiology · 2024
DOI: 10.3389/fcimb.2024.1450199 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Cellular and Infection Microbiology, 2024. Verfasst von Yizhe Wang und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Laboratory, The First People's Hospital of Guiyang, Guiyang, Guizhou, China. Hauptthemen laut MEDLINE: Candida albicans, Nucleic Acid Amplification Techniques, Molecular Diagnostic Techniques, Sensitivity and Specificity. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Introduction
Candida albicans ( C. albicans , CA) is an essential invasive fungus in clinical diagnosis. Although several detection methods exist, none meet the need for early diagnosis. A rapid, sensitive, and specific diagnostic tool is crucial for effective prevention and control of C. albicans infections.
Methods
This study aimed to develop a new, rapid, and ultrasensitive diagnostic tool for C. albicans detection based on restriction endonuclease-mediated real-time loop-mediated isothermal amplification (ERT-LAMP-CA). The ERT-LAMP-CA technology combines LAMP amplification, restriction endonuclease cleavage, and real-time fluorescence detection in a single reaction tube, which can complete a diagnosis of C. albicans in a short time (approximately 1 h).
Results
Herein, we developed the primer sequences required for ERT-LAMP-CA based on the ITS2 gene of C. albicans and found that ERT-LAMP-CA limit of detection was approximately 500 ag/μL genomic DNA and can present negative results for non- C. albicans templates. We tested sputum samples from 64 patients with suspected C. albicans infections to validate ERT-LAMP-CA applicability in clinical sample testing and found that ERT-LAMP-CA was consistent with multiplex PCR-capillary electrophoresis.
Discussion
In conclusion, ERT-LAMP-CA is a rapid, accurate, and sensitive assay with excellent potential for clinical and basic laboratory diagnosis and an efficient screening strategy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Clinical Laboratory, The First People's Hospital of Guiyang, Guiyang, Guizhou, China.
Zitieren
APA
Wang, Y., Zhou, Y., Lu, J., Yu, H., & Wang, Y. (2024). A novel, rapid, ultrasensitive diagnosis platform for detecting Candida albicans using restriction endonuclease‐mediated real-time loop-mediated isothermal amplification. Frontiers in Cellular and Infection Microbiology. https://doi.org/10.3389/fcimb.2024.1450199
Vancouver
Wang Y, Zhou Y, Lu J, Yu H, Wang Y. A novel, rapid, ultrasensitive diagnosis platform for detecting Candida albicans using restriction endonuclease‐mediated real-time loop-mediated isothermal amplification. Frontiers in Cellular and Infection Microbiology. 2024. doi:10.3389/fcimb.2024.1450199
BibTeX
@article{Wang2024,
author = {Wang, Yizhe and Zhou, Yuhong and Lu, Jingrun and Yu, Honglan and Wang, Yu},
title = {A novel, rapid, ultrasensitive diagnosis platform for detecting Candida albicans using restriction endonuclease‐mediated real-time loop-mediated isothermal amplification},
journal = {Frontiers in Cellular and Infection Microbiology},
year = {2024},
doi = {10.3389/fcimb.2024.1450199}
}
EUVIMED