TB LAMP assay, a beneficial tool for the diagnosis of Tubercular meningitis in resource-limited settings
The Journal of Infection in Developing Countries · 2024
DOI: 10.3855/jidc.18115 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Infection in Developing Countries, 2024. Verfasst von Vineeta Mittal und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Microbiology, Dr Ram Manohar Lohia Institute of Medical Sciences, Lucknow, India. Hauptthemen laut MEDLINE: Tuberculosis, Meningeal, Mycobacterium tuberculosis, Nucleic Acid Amplification Techniques, Molecular Diagnostic Techniques. Die Arbeit wurde bisher 1-mal zitiert (Crossref). Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Introduction
Tubercular meningitis (TBM) is a serious public health problem in developing countries as it leads to significant mortality and residual neurological sequelae. The estimated mortality due to TBM in India is 1.5 per 100,000 population. In resource-limited settings, only the Ziehl-Neelsen (ZN) stain, which has very little sensitivity, is available. The World Health Organization recommended the Loop Mediated Isothermal Amplification (TB LAMP) assay for pulmonary tuberculosis only. We evaluated this test for tubercular meningitis as well. Methodology: In a cross-sectional study of 2-year duration, we have taken 239 cerebrospinal fluid samples from suspected cases of tubercular meningitis patients. ZN staining along with Mycobacteria Growth Indicator Tube (MGIT) TB culture, Xpert MTB/RIF Ultra assay, and commercial TB LAMP assay were performed for each sample.
Results
Out of 239 samples, 40 samples (16.73%) were found TB LAMP assay positive, 48 samples (20.08%) were found Xpert ultra-assay positive, 12 samples (5.02%) were MGIT TB culture positive and acid-fast bacillus smear positive in ten samples (4.18 %). Out of 12 MGIT-positive samples, all samples (100%) were TB LAMP and Xpert ultra positive and one sample (8.33%) was ZN smear positive. In 199 negative samples from the TB LAMP assay, eight samples were positive by Xpert, none by MGIT TB culture and AFB smear. Sensitivity and specificity were found as 100% and 87.66%, respectively, for the TB LAMP assay.
Conclusion
TB LAMP assay is a rapid, cost-effective, sensitive, and specific test for tubercular meningitis infection in resource-limited settings.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Microbiology, Dr Ram Manohar Lohia Institute of Medical Sciences, Lucknow, India.
- Department of Neurology, Dr Ram Manohar Lohia Institute of Medical Sciences, Lucknow, India.
Zitieren
APA
Mittal, V., Kumar, M., & Singh, A. K. (2024). TB LAMP assay, a beneficial tool for the diagnosis of Tubercular meningitis in resource-limited settings. The Journal of Infection in Developing Countries. https://doi.org/10.3855/jidc.18115
Vancouver
Mittal V, Kumar M, Singh AK. TB LAMP assay, a beneficial tool for the diagnosis of Tubercular meningitis in resource-limited settings. The Journal of Infection in Developing Countries. 2024. doi:10.3855/jidc.18115
BibTeX
@article{Mittal2024,
author = {Mittal, Vineeta and Kumar, Manoj and Singh, Ajay Kumar},
title = {TB LAMP assay, a beneficial tool for the diagnosis of Tubercular meningitis in resource-limited settings},
journal = {The Journal of Infection in Developing Countries},
year = {2024},
doi = {10.3855/jidc.18115}
}