Direction-dependent biomechanical effects of transverse process hooks versus pedicle screws at the uppermost instrumented vertebra in adult spinal deformity: a finite element analysis
Frontiers in Bioengineering and Biotechnology · 25.09.2026 · 14
DOI: 10.3389/fbioe.2026.1937182 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Bioengineering and Biotechnology, online erschienen am 25.09.2026. Verfasst von Sun-Joon Yoo und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurosurgery, Inha University College of Medicine, Incheon, Republic of Korea. Die Arbeit nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Proximal junctional complications are often driven by abrupt mechanical transition at the uppermost instrumented vertebra (UIV). This study used patient-specific finite element analysis to compare biomechanical effects of transverse process hooks and pedicle screws at the UIV, specifically examining how hook orientation influences anterior-posterior load sharing. A validated nonlinear three-dimensional T7–L2 spinal model was developed using data from a 60-year-old woman. Three UIV constructs were evaluated at T9: bilateral pedicle screws (BPS) and downward and upward facing transverse process hook (TPH) configurations. Under a 500-N follower load and 8-Nm bending moments, we analyzed facet joint load (FJL), range of motion (ROM), intradiscal pressure, and mechanical failure risk. In flexion, FJL at the UIV+1/UIV level decreased by 6.2% and 19.6% in the downward-facing and upward-facing TPH models, respectively, compared with the BPS model. In extension, FJL decreased by 4.2% in the upward-facing TPH model, but increased by 32.4% in the downward-facing TPH model, relative to the BPS model. Both TPH models preserved greater UIV ROM than the bilateral pedicle screw model, with the upward-facing configuration achieving the highest flexion ROM (2.1°) and the downward-facing configuration achieving the highest extension ROM (3.2°). In the BPS model, UIV screw pull-out risk was 136% in flexion. Conversely, the risks of transverse process breakage for the downward-facing and upward-facing TPH models were substantially lower (50% and 42%, respectively). Hook constructs increased screw pull-out risk at the UIV-1 level compared with the BPS model. Using the TPH at the UIV can facilitate a biomechanical “soft landing” by preserving segmental motion and reducing posterior load at adjacent levels. These effects are orientation-dependent, with the upward-facing TPH configuration potentially offering greater advantage in preserving segmental motion during flexion. Surgical strategies should be tailored to individual bone quality due to potential stress transfer to the UIV-1 level.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Neurosurgery, Inha University College of Medicine, Incheon, Republic of Korea.
- Department of Neurosurgery, Spine and Spinal Cord Institute, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea.
- RAIDAM Co. Ltd., Wonju, Republic of Korea.
- CGBio Co. Ltd., Seoul, Republic of Korea.
- Department of Neurosurgery, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.
Zitieren
APA
Yoo, S. J., Moon, B. J., Eom, J. D., Won, Y. H., Oh, J. K., & Kim, K. H. (2026). Direction-dependent biomechanical effects of transverse process hooks versus pedicle screws at the uppermost instrumented vertebra in adult spinal deformity: a finite element analysis. Frontiers in Bioengineering and Biotechnology, 14. https://doi.org/10.3389/fbioe.2026.1937182
Vancouver
Yoo SJ, Moon BJ, Eom JD, Won YH, Oh JK, Kim KH. Direction-dependent biomechanical effects of transverse process hooks versus pedicle screws at the uppermost instrumented vertebra in adult spinal deformity: a finite element analysis. Frontiers in Bioengineering and Biotechnology. 2026;14. doi:10.3389/fbioe.2026.1937182
BibTeX
@article{Yoo2026,
author = {Yoo, Sun-Joon and Moon, Bong-Ju and Eom, Jung-Do and Won, Young-Hoon and Oh, Jae Keun and Kim, Kyung-Hyun},
title = {Direction-dependent biomechanical effects of transverse process hooks versus pedicle screws at the uppermost instrumented vertebra in adult spinal deformity: a finite element analysis},
journal = {Frontiers in Bioengineering and Biotechnology},
year = {2026},
volume = {14},
doi = {10.3389/fbioe.2026.1937182}
}
EUVIMED