The possibility of clinical bonding between metal/ceramic brackets to zirconia: in vitro study
Frontiers in Bioengineering and Biotechnology · 15.01.2024 · 12
DOI: 10.3389/fbioe.2024.1354241 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Bioengineering and Biotechnology, online erschienen am 15.01.2024. Verfasst von Yichun Hu und 8 weiteren Autor:innen. Beteiligte Einrichtung: School and Hospital of Stomatology, China Medical University, Shenyang, China. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objective
The present study aimed to assess the bond strength and durability of six bonding agents concerning their application to metal or ceramic brackets and zirconia. Materials and Methods: Six resin cement bonding agents (XT, XTS, RSBU, RGBU, SBPM, and GMP) were chosen for this investigation. Specimens were either stored in distilled water at 37°C for 24 h or subjected to 5,000 thermocycles before conducting a Shear Bond Strength (SBS) test. Statistical analysis of the SBS data was performed using three-way ANOVA and Games-Howell tests (α = 0.05). The Adhesive Remnant Index was examined, and the debonding surface details on brackets and zirconia were observed.
Results
For metal brackets, all groups demonstrated clinically acceptable bond strength, irrespective of storage conditions, except for the XT group. Regarding ceramic brackets, all groups displayed acceptable bond strength after 24 h of water storage. However, following thermocycling, a significant decrease in SBS was noted across all groups ( p < 0.05), with SBPM exhibiting a higher bond strength. Three-way ANOVA analysis indicated that SBS values were notably influenced by each factor, and an interaction among the three independent variables was observed ( p = 0.000).
Conclusion
The reliable bond strength between ceramic brackets and zirconia was significantly lower after thermocycling compared to that of metal brackets and zirconia. SBPM exhibited consistent and robust bond strength between ceramic/metal brackets and zirconia across various storage conditions. Furthermore, the HEMA-free adhesive demonstrated a potentially more consistent bonding performance compared to the HEMA-containing adhesive employed in this study.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School and Hospital of Stomatology, China Medical University, Shenyang, China.
- Department of Dental Materials Science, The Second Department of Prosthodontics, School and Hospital of Stomatology, China Medical University, Shenyang, China.
- Department of Restorative Dentistry, Division of Oral Health Science, Faculty of Dental Medicine, Hokkaido University, Sapporo, Japan.
- Department of Oral Biological and Medical Sciences, Division of Biomaterials, Faculty of Dentistry, University of British Columbia, Vancouver, BC, Canada.
Zitieren
APA
Hu, Y., Gao, J., Huang, X., Li, Y., Chen, Z., Zhan, D., Sano, H., Carvalho, R. M., & Fu, J. (2024). The possibility of clinical bonding between metal/ceramic brackets to zirconia: in vitro study. Frontiers in Bioengineering and Biotechnology, 12. https://doi.org/10.3389/fbioe.2024.1354241
Vancouver
Hu Y, Gao J, Huang X, Li Y, Chen Z, Zhan D, et al. The possibility of clinical bonding between metal/ceramic brackets to zirconia: in vitro study. Frontiers in Bioengineering and Biotechnology. 2024;12. doi:10.3389/fbioe.2024.1354241
BibTeX
@article{Hu2024,
author = {Hu, Yichun and Gao, Jiayang and Huang, Xinyue and Li, Yutong and Chen, Ziyi and Zhan, Desong and Sano, Hidehiko and Carvalho, Ricardo M and Fu, Jiale},
title = {The possibility of clinical bonding between metal/ceramic brackets to zirconia: in vitro study},
journal = {Frontiers in Bioengineering and Biotechnology},
year = {2024},
volume = {12},
doi = {10.3389/fbioe.2024.1354241}
}
EUVIMED