EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Biomechanical comparison of all-on-4 and all-on-5 implant-supported prostheses with alteration of anterior-posterior spread: a three-dimensional finite element analysis

Xin Sun, Kangjie Cheng, Yunfeng Liu, Sipeng Ke, Wentao Zhang, Linhong Wang, Fan Yang

Frontiers in Bioengineering and Biotechnology · 16.06.2023 · 11

DOI: 10.3389/fbioe.2023.1187504 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Bioengineering and Biotechnology, online erschienen am 16.06.2023. Verfasst von Xin Sun und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Stomatology, Zhejiang Chinese Medical University, Hangzhou, Zhejiang, China. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Medical Science and Technology Project of Zhejiang Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

The all-on-4 concept is widely used in clinical practice. However, the biomechanical changes following the alteration of anterior-posterior (AP) spread in all-on-4 implant-supported prostheses have not been extensively studied.

Methods

Three-dimensional finite element analysis was used to compare the biomechanical behavior of all-on-4 and all-on-5 implant-supported prostheses with a change in anterior-posterior (AP) spread. A three-dimensional finite element analysis was performed on a geometrical mandible model containing 4 or 5 implants. Four different implant configurations were modeled by varying the angle of inclination of the distal implants (0°and 30°), including all-on-4a, all-on-4b, all-on-5a, and all-on-5b, and a 100 N force was successively applied to the anterior and unilateral posterior teeth to observe and analyze the differences in the biomechanical behavior of each model under the static influence at different position.

Results

Adding an anterior implant to the dental arch according to the all-on-4 concept with a distal 30° tilt angle implant exhibited the best biomechanical behavior. However, when the distal implant was implanted axially, there was no significant difference between the all-on-4 and all-on-5 groups.

Discussion

In the all-on-5 group, increasing the AP spread with tilted terminal implants showed better biomechanical behavior. It can be concluded that placing an additional implant in the midline of the atrophic edentulous mandible and increasing the AP spread might be beneficial in improving the biomechanical behavior of tilted distal implants.

Schlagwörter

Stichwörter der Autor:innen

all-on-4all-on-5anterior-posterior spreadbiomechanicsthree-dimensional finite element analysis

Autor:innen und Institutionen

  • Department of Stomatology, Zhejiang Chinese Medical University, Hangzhou, Zhejiang, China.
  • College of Mechanical Engineering, Zhejiang University of Technology, Hangzhou, China.
  • Key Laboratory of Special Purpose Equipment and Advanced Processing Technology, Ministry of Education and Zhejiang Province, Zhejiang University of Technology, Hangzhou, China.
  • National International Joint Research Center of Special Purpose Equipment and Advanced Processing Technology, Zhejiang University of Technology, Hangzhou, China.
  • Center for Plastic and Reconstructive Surgery, Department of Stomatology, Zhejiang Provincial People's Hospital, Affiliated People's Hospital, Hangzhou Medical College, Hangzhou, Zhejiang, China.

Förderung

  • Medical Science and Technology Project of Zhejiang Province

Zitieren

APA

Sun, X., Cheng, K., Liu, Y., Ke, S., Zhang, W., Wang, L., & Yang, F. (2023). Biomechanical comparison of all-on-4 and all-on-5 implant-supported prostheses with alteration of anterior-posterior spread: a three-dimensional finite element analysis. Frontiers in Bioengineering and Biotechnology, 11. https://doi.org/10.3389/fbioe.2023.1187504

Vancouver

Sun X, Cheng K, Liu Y, Ke S, Zhang W, Wang L, et al. Biomechanical comparison of all-on-4 and all-on-5 implant-supported prostheses with alteration of anterior-posterior spread: a three-dimensional finite element analysis. Frontiers in Bioengineering and Biotechnology. 2023;11. doi:10.3389/fbioe.2023.1187504

BibTeX
@article{Sun2023,
  author = {Sun, Xin and Cheng, Kangjie and Liu, Yunfeng and Ke, Sipeng and Zhang, Wentao and Wang, Linhong and Yang, Fan},
  title = {Biomechanical comparison of all-on-4 and all-on-5 implant-supported prostheses with alteration of anterior-posterior spread: a three-dimensional finite element analysis},
  journal = {Frontiers in Bioengineering and Biotechnology},
  year = {2023},
  volume = {11},
  doi = {10.3389/fbioe.2023.1187504}
}
Kostenlos starten →