EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Near infrared spectroscopy assessment of wrist-based vascular occlusion protocols

Vanja Dvekar, Faraz Sadrzadeh-Afsharazar, Leah DeVos, Gennadi Saiko, Alexandre Douplik

Advanced Optical Technologies · 29.12.2025 · 14

DOI: 10.3389/aot.2025.1707828 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advanced Optical Technologies, online erschienen am 29.12.2025. Verfasst von Vanja Dvekar und 4 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Vascular occlusion tests (VOTs) are widely used to assess microvascular function with near-infrared spectroscopy (NIRS), but protocols vary substantially, particularly in occlusion pressure and anatomical site. Most studies focus on the upper arm or thigh, with few studying distal limbs such as the wrist, highlighting the importance of standardizing wrist-based arterial occlusion pressures.

Methods

To address this gap, the present study examined the effects of two fixed occlusion pressures, 150 mmHg and 200 mmHg, applied at the wrist on the local muscle oxygenation dynamics. A total of 21 healthy participants underwent an 8-min experimental protocol comprising a 1-min baseline (no pressure), 3-min occlusion, and 4-min reperfusion period. Muscle oxygenation was continuously monitored from the thenar eminence of the occluded hand using a commercial near-infrared spectroscopy (NIRS) device (Moxy, Hutchinson, USA).

Results

Reactive hyperemia responses at the two pressures were compared for five distinct metrics: amplitude of muscle oxygen saturation ( S m O 2 ) ( p = 0.0065 ) , time to maximum S m O 2 ( p = 0.235 ) , and three first-derivative features: time to peak slope ( p = 0.694 ) , peak slope value ( p = 0.019 ) , and full width at half maximum (FWHM) ( p = 0.46 ) . Statistically significant differences were observed in amplitude of S m O 2 , and peak slope value. However, the temporal metrics such as time to max S m O 2 , time at peak slope value, and FWHM, were not significantly different.

Conclusion

Overall, this study supports the potential of wrist-based AOP protocols and highlights the importance of selecting appropriate occlusion pressures and anatomical sites to optimize vascular response while minimizing patient discomfort. Given the wrist’s anatomical advantages, incorporating wrist-based occlusion into daily practice and clinical assessments may enhance its translational potential as a pressure occlusion site.

Zitieren

APA

Dvekar, V., Sadrzadeh-Afsharazar, F., DeVos, L., Saiko, G., & Douplik, A. (2025). Near infrared spectroscopy assessment of wrist-based vascular occlusion protocols. Advanced Optical Technologies, 14. https://doi.org/10.3389/aot.2025.1707828

Vancouver

Dvekar V, Sadrzadeh-Afsharazar F, DeVos L, Saiko G, Douplik A. Near infrared spectroscopy assessment of wrist-based vascular occlusion protocols. Advanced Optical Technologies. 2025;14. doi:10.3389/aot.2025.1707828

BibTeX
@article{Dvekar2025,
  author = {Dvekar, Vanja and Sadrzadeh-Afsharazar, Faraz and DeVos, Leah and Saiko, Gennadi and Douplik, Alexandre},
  title = {Near infrared spectroscopy assessment of wrist-based vascular occlusion protocols},
  journal = {Advanced Optical Technologies},
  year = {2025},
  volume = {14},
  doi = {10.3389/aot.2025.1707828}
}
Kostenlos starten →