EUVIMEDEuropean Health Evidence
Uhr 10/10Sources Journal Tree
Easy Demo

Lokaler Crossref-Datenbestand · journal-article

Concurrent validity of a novel digital dynamometer for assessing performance on the Cranio-Cervical Flexion Test

Marco Barbero, Daniele Lonati, Marco Griseri, Corrado Cescon, Alessandro Bonafine, Tiziano Negrisolo, Emanuele Falzone, Samuel Pedrucci, Erik Cattrysse, Deborah Falla

Archives of Physiotherapy · 2026

Vollständiger Abstract

Worum geht es in dieser Arbeit?

Introduction: The Cranio-Cervical Flexion Test (CCFT) is a validated clinical test used to evaluate deep cervical flexor muscle function. A pressure biofeedback unit (PBU) has traditionally been the reference device. Recently, a new portable digital device known as the Neuromuscular Cranio-cervical Device (NOD) has been developed as a potential alternative.Methods: In this cross-sectional concurrent validation study, 88 participants were recruited from four outpatient physiotherapy practices, including individuals with current neck pain and individuals with a previous history of neck pain. All participants performed the CCFT using both devices. The PBU was inflated to a baseline pressure of 20 mmHg, with the participant then performing C-CF to increase the pressure in increments of 2 mmHg over five progressive stages, while the NOD was calibrated to corresponding force targets. Agreement and concurrent validity between the devices were assessed, and C-CF range of motion (ROM) was analyzed using linear mixed-effects models.Results: Agreement between CCFT performance scores obtained with the NOD and the PBU was 94.3%, with a very strong positive correlation (Spearman’s ρ = 0.930, p < 0.001). The NOD measured slightly greater C-CF ROM than the PBU (mean difference 0.68°), with significant differences at lower CCFT stages that converged at higher stages of the test.Conclusion: These findings demonstrate strong concurrent validity between the NOD and the PBU, supporting the NOD as a valid digital alternative for assessment of the CCFT.

Bibliografischer Nachweis

Publikationsdaten

Autor:innen
Marco Barbero, Daniele Lonati, Marco Griseri, Corrado Cescon, Alessandro Bonafine, Tiziano Negrisolo, Emanuele Falzone, Samuel Pedrucci, Erik Cattrysse, Deborah Falla
Quelle
Archives of Physiotherapy
Publikation
2026-01-01
Band / Ausgabe
Nicht angegeben
Seiten
Nicht angegeben
ISSN / ISBN
2057-0082, 2057-0082
Zitationen
0 laut Crossref
Referenzen
0 hinterlegt

Zitieren

Zitierfähiger Nachweis

Marco Barbero, Daniele Lonati, Marco Griseri, Corrado Cescon, Alessandro Bonafine, Tiziano Negrisolo, Emanuele Falzone, Samuel Pedrucci, Erik Cattrysse, Deborah Falla (2026). Concurrent validity of a novel digital dynamometer for assessing performance on the Cranio-Cervical Flexion Test. Archives of Physiotherapy. https://doi.org/10.33393/aop.2026.3947
RIS BibTeX CSL-JSON

Kontext

Themen, Förderung und Nutzung

Lizenzhinweise: Lizenz 1