EUVIMEDEUVIMED entdecken
Open Access · CC BY-SA 4.0

Implant Design Femur Bone using CAD Computation with Variation in Implant Plate Length

Oka Akbar Sudrajat, Ladya Cheril Az Zahra, Arum Sinda Santika, Dira Ernawati, Akbar Sujiwa

FARADAY · 2025

DOI: 10.33005/faraday.v1i1.9 ↗

Kurz gefasst

Fachartikel in der Zeitschrift FARADAY, 2025. Verfasst von Oka Akbar Sudrajat und 4 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-SA 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Femoral fractures are among the most common and severe musculoskeletal injuries, necessitating effective and reliable treatment strategies. This study explores the biomechanical performance of femur implants by evaluating the effects of material selection and implant design using the finite element method (FEM). Three biocompatible materials—titanium alloy Ti-6Al-4V, stainless steel, and PEEK—were analyzed under linear elastic isotropic conditions. Implant designs varied in length (10.02 mm, 13.37 mm, and 15.60 mm) with a fixed head thickness of 3 mm. Simulations assessed stress distribution, deformation, and overall structural performance under physiological loading conditions. Results demonstrated that implant length significantly affects mechanical behavior. The 15.60 mm implants exhibited the most uniform stress distribution and minimal deformation, indicating superior mechanical stability. In contrast, shorter implants (e.g., 10.02 mm) showed increased stress concentrations and deformation, suggesting a higher risk of mechanical failure. Among the materials tested, Ti-6Al-4V outperformed others due to its favorable combination of strength and biocompatibility. The study concludes that longer implants made from titanium alloy provide improved structural integrity, offering safer and more durable options for femoral fracture repair. These findings contribute to the optimization of implant design for enhanced clinical outcomes in orthopedic applications

Zitieren

APA

Sudrajat, O. A., Zahra, L. C. A., Santika, A. S., Ernawati, D., & Sujiwa, A. (2025). Implant Design Femur Bone using CAD Computation with Variation in Implant Plate Length. FARADAY. https://doi.org/10.33005/faraday.v1i1.9

Vancouver

Sudrajat OA, Zahra LCA, Santika AS, Ernawati D, Sujiwa A. Implant Design Femur Bone using CAD Computation with Variation in Implant Plate Length. FARADAY. 2025. doi:10.33005/faraday.v1i1.9

BibTeX
@article{Sudrajat2025,
  author = {Sudrajat, Oka Akbar and Zahra, Ladya Cheril Az and Santika, Arum Sinda and Ernawati, Dira and Sujiwa, Akbar},
  title = {Implant Design Femur Bone using CAD Computation with Variation in Implant Plate Length},
  journal = {FARADAY},
  year = {2025},
  doi = {10.33005/faraday.v1i1.9}
}
Kostenlos starten →