EUVIMEDEUVIMED entdecken
Open Access · CC BY-SA 4.0

False negative bronchial artery caliber on multi-detector computed tomography in predicting outcome of bronchial artery embolization in patient with haemoptysis

Tze Hui Soo, Anas Tharek, Idris Ibrahim, Mohd Hazeman Zakaria, Mohd Naim Mohd Yaakob, Mohammad Fandi Al-Khafiz Kamis, Mawaddah Abdul Malik

The Interventionalist Journal · 2022

DOI: 10.32896/tij.v2n3.12-15 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Interventionalist Journal, 2022. Verfasst von Tze Hui Soo und 6 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-SA 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Bronchial artery embolization was first performed in 1973 by Remy et al with widespread acceptance since then. Multi-detector computed tomography (MDCT) CT angiography (CTA) is currently the gold standard imaging modality used to identify the site and cause of bleeding in patient presented with haemoptysis. Bronchial artery anatomies and precise location can be obtained by scrutinizing CTA prior to interventional procedures. CTA has the advantage of not only can preclude the need of digital subtraction angiography (DSA) in inappropriate cases, but also can shorten the intervention procedure timing. We present a case of false negative bronchial artery caliber seen on MDCT which was abnormal in DSA.

Zitieren

APA

Soo, T. H., Tharek, A., Ibrahim, I., Zakaria, M. H., Yaakob, M. N. M., Kamis, M. F. A., & Malik, M. A. (2022). False negative bronchial artery caliber on multi-detector computed tomography in predicting outcome of bronchial artery embolization in patient with haemoptysis. The Interventionalist Journal. https://doi.org/10.32896/tij.v2n3.12-15

Vancouver

Soo TH, Tharek A, Ibrahim I, Zakaria MH, Yaakob MNM, Kamis MFA, et al. False negative bronchial artery caliber on multi-detector computed tomography in predicting outcome of bronchial artery embolization in patient with haemoptysis. The Interventionalist Journal. 2022. doi:10.32896/tij.v2n3.12-15

BibTeX
@article{Soo2022,
  author = {Soo, Tze Hui and Tharek, Anas and Ibrahim, Idris and Zakaria, Mohd Hazeman and Yaakob, Mohd Naim Mohd and Kamis, Mohammad Fandi Al-Khafiz and Malik, Mawaddah Abdul},
  title = {False negative bronchial artery caliber on multi-detector computed tomography in predicting outcome of bronchial artery embolization in patient with haemoptysis},
  journal = {The Interventionalist Journal},
  year = {2022},
  doi = {10.32896/tij.v2n3.12-15}
}
Kostenlos starten →