Fachartikel in der Zeitschrift MedPharmRes, online erschienen am 30.06.2026. Verfasst von Nhan Thanh Vo und 5 weiteren Autor:innen. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Tam Anh General Hospital.
Abstract (Originalsprache)
In-stent restenosis (ISR) remains a frequent cause of stent failure after percutaneous coronary intervention (PCI) and continues to contribute substantially to repeat coronary revascularization. Intracoronary optical coherence tomography (OCT) provides high-resolution imaging that enables detailed characterization of ISR mechanisms, thereby facilitating individualized treatment strategies. Lipoprotein(a) is a well-established risk factor for coronary artery disease, and emerging evidence suggests a potential association between elevated Lp(a) levels and ISR. We present a case series of three patients who developed symptomatic ISR following drug-eluting stent implantation. All patients underwent comprehensive clinical evaluation and coronary angiography, followed by intracoronary OCT imaging to identify the underlying ISR mechanisms, including neointimal hyperplasia, neoatherosclerosis, and stent-related mechanical factors. Serum Lp(a) levels were measured in all cases. Treatment strategies were selected based on OCT findings and individual clinical characteristics. OCT imaging revealed distinct ISR mechanisms across the three cases. Elevated Lp(a) levels were observed in all patients, although the degree of elevation varied considerably. OCT-guided, mechanism-specific treatment strategies were successfully implemented in each case, resulting in optimal angiographic outcomes and clinical improvement at the one-month follow-up. This case series highlights the value of OCT in elucidating heterogeneous mechanisms of ISR and guiding individualized treatment approaches. Elevated Lp(a) levels were observed in all cases; however, given the descriptive nature and small sample size of this report, no conclusions regarding causality or clinical association can be drawn.
Förderung
- Tam Anh General Hospital
Zitieren
APA
Vo, N. T., Duong, T. N. T., Nguyen, D. V., Nguyen, C. M., Pham, H. T. H., & Vo, N. T. (2026). Lipoprotein(a) and optical coherence tomography–based characterization of in-stent restenosis: a case series. MedPharmRes, 10(2), 261-269. https://doi.org/10.32895/mpr.26.00031
Vancouver
Vo NT, Duong TNT, Nguyen DV, Nguyen CM, Pham HTH, Vo NT. Lipoprotein(a) and optical coherence tomography–based characterization of in-stent restenosis: a case series. MedPharmRes. 2026;10(2):261-269. doi:10.32895/mpr.26.00031
BibTeX
@article{Vo2026,
author = {Vo, Nhan Thanh and Duong, Tram Ngoc Toa and Nguyen, Duong Van and Nguyen, Chau Minh and Pham, Hieu Trong Hoang and Vo, Nhan Thanh},
title = {Lipoprotein(a) and optical coherence tomography–based characterization of in-stent restenosis: a case series},
journal = {MedPharmRes},
year = {2026},
volume = {10},
number = {2},
pages = {261--269},
doi = {10.32895/mpr.26.00031}
}
EUVIMED