EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Optical coherence tomography (OCT) vs intravascular ultrasound (IVUS) in diagnosing the mechanisms of in-stent restenosis in drug eluting stents

Moustafa Kamal Eldin Ibrahim Khalil Saad, Ahmad Abdelaziz, Fatma Fathelbab, Mahmoud Mohamed Mahmoud Abdallah elmallawany, Khalied Ahmad Emam Elkashab

Romanian Journal of Cardiology · 01.06.2026 · 36 (2) · 122-126

DOI: 10.2478/rjc-2026-0006 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Romanian Journal of Cardiology, online erschienen am 19.03.2026. Verfasst von Moustafa Kamal Eldin Ibrahim Khalil Saad und 4 weiteren Autor:innen. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

In-stent restenosis remains a recognized complication of percutaneous coronary intervention (PCI). Conventional two-dimensional angiography is limited to visualization of the coronary lumen and provides inadequate assessment of in-stent restenosis mechanisms. In contrast, intracoronary imaging modalities such as intravascular ultrasound (IVUS) and optical coherence tomography (OCT) enable detailed evaluation of in-stent restenosis, optimization of procedural outcomes, and improvement of long-term clinical results.

Aims

The aim of this study was to compare OCT and IVUS in detecting the mechanisms of in-stent restenosis and to evaluate their role in guiding management, whether through balloon angioplasty or repeat PCI with stent implantation. Materials and methods The study included 50 patients who had previously deployed stents presenting to our hospital, in the period from November 2022 to December 2024, with angina refractory to medical therapy. All of whom underwent comprehensive clinical evaluation including history, physical examination, ECG, echocardiography, and coronary angiography. Patients were divided randomly into two groups: Group 1 (n=25) underwent IVUS-guided PCI, while Group 2 (n=25) underwent OCT-guided PCI.

Results

OCT was significantly superior to IVUS in detecting mal-apposition (p = 0.015) and neo-atherosclerosis (p = 0.018) as mechanisms of in-stent restenosis. No statistically significant differences were observed between OCT and IVUS in detecting neointimal hyperplasia (p = 0.713), under-expansion (p = 0.077), or edge dissection (p = 0.269).

Conclusion

Intracoronary imaging is a valuable tool for identifying the mechanisms of in-stent restenosis, guiding tailored therapy, and improving clinical outcomes. OCT offers superior diagnostic capability compared with IVUS, particularly in detecting mal-apposition and neo-atherosclerosis.

Zitieren

APA

Saad, M. K. E. I. K., Abdelaziz, A., Fathelbab, F., elmallawany, M. M. M. A., & Elkashab, K. A. E. (2026). Optical coherence tomography (OCT) vs intravascular ultrasound (IVUS) in diagnosing the mechanisms of in-stent restenosis in drug eluting stents. Romanian Journal of Cardiology, 36(2), 122-126. https://doi.org/10.2478/rjc-2026-0006

Vancouver

Saad MKEIK, Abdelaziz A, Fathelbab F, elmallawany MMMA, Elkashab KAE. Optical coherence tomography (OCT) vs intravascular ultrasound (IVUS) in diagnosing the mechanisms of in-stent restenosis in drug eluting stents. Romanian Journal of Cardiology. 2026;36(2):122-126. doi:10.2478/rjc-2026-0006

BibTeX
@article{Saad2026,
  author = {Saad, Moustafa Kamal Eldin Ibrahim Khalil and Abdelaziz, Ahmad and Fathelbab, Fatma and elmallawany, Mahmoud Mohamed Mahmoud Abdallah and Elkashab, Khalied Ahmad Emam},
  title = {Optical coherence tomography (OCT) vs intravascular ultrasound (IVUS) in diagnosing the mechanisms of in-stent restenosis in drug eluting stents},
  journal = {Romanian Journal of Cardiology},
  year = {2026},
  volume = {36},
  number = {2},
  pages = {122--126},
  doi = {10.2478/rjc-2026-0006}
}
Kostenlos starten →