Optical coherence tomography (OCT) vs intravascular ultrasound (IVUS) in diagnosing the mechanisms of in-stent restenosis in drug eluting stents
Romanian Journal of Cardiology · 01.06.2026 · 36 (2) · 122-126
DOI: 10.2478/rjc-2026-0006 ↗Kurz gefasst
Fachartikel in der Zeitschrift Romanian Journal of Cardiology, online erschienen am 19.03.2026. Verfasst von Moustafa Kamal Eldin Ibrahim Khalil Saad und 4 weiteren Autor:innen. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
In-stent restenosis remains a recognized complication of percutaneous coronary intervention (PCI). Conventional two-dimensional angiography is limited to visualization of the coronary lumen and provides inadequate assessment of in-stent restenosis mechanisms. In contrast, intracoronary imaging modalities such as intravascular ultrasound (IVUS) and optical coherence tomography (OCT) enable detailed evaluation of in-stent restenosis, optimization of procedural outcomes, and improvement of long-term clinical results.
Aims
The aim of this study was to compare OCT and IVUS in detecting the mechanisms of in-stent restenosis and to evaluate their role in guiding management, whether through balloon angioplasty or repeat PCI with stent implantation. Materials and methods The study included 50 patients who had previously deployed stents presenting to our hospital, in the period from November 2022 to December 2024, with angina refractory to medical therapy. All of whom underwent comprehensive clinical evaluation including history, physical examination, ECG, echocardiography, and coronary angiography. Patients were divided randomly into two groups: Group 1 (n=25) underwent IVUS-guided PCI, while Group 2 (n=25) underwent OCT-guided PCI.
Results
OCT was significantly superior to IVUS in detecting mal-apposition (p = 0.015) and neo-atherosclerosis (p = 0.018) as mechanisms of in-stent restenosis. No statistically significant differences were observed between OCT and IVUS in detecting neointimal hyperplasia (p = 0.713), under-expansion (p = 0.077), or edge dissection (p = 0.269).
Conclusion
Intracoronary imaging is a valuable tool for identifying the mechanisms of in-stent restenosis, guiding tailored therapy, and improving clinical outcomes. OCT offers superior diagnostic capability compared with IVUS, particularly in detecting mal-apposition and neo-atherosclerosis.
Zitieren
APA
Saad, M. K. E. I. K., Abdelaziz, A., Fathelbab, F., elmallawany, M. M. M. A., & Elkashab, K. A. E. (2026). Optical coherence tomography (OCT) vs intravascular ultrasound (IVUS) in diagnosing the mechanisms of in-stent restenosis in drug eluting stents. Romanian Journal of Cardiology, 36(2), 122-126. https://doi.org/10.2478/rjc-2026-0006
Vancouver
Saad MKEIK, Abdelaziz A, Fathelbab F, elmallawany MMMA, Elkashab KAE. Optical coherence tomography (OCT) vs intravascular ultrasound (IVUS) in diagnosing the mechanisms of in-stent restenosis in drug eluting stents. Romanian Journal of Cardiology. 2026;36(2):122-126. doi:10.2478/rjc-2026-0006
BibTeX
@article{Saad2026,
author = {Saad, Moustafa Kamal Eldin Ibrahim Khalil and Abdelaziz, Ahmad and Fathelbab, Fatma and elmallawany, Mahmoud Mohamed Mahmoud Abdallah and Elkashab, Khalied Ahmad Emam},
title = {Optical coherence tomography (OCT) vs intravascular ultrasound (IVUS) in diagnosing the mechanisms of in-stent restenosis in drug eluting stents},
journal = {Romanian Journal of Cardiology},
year = {2026},
volume = {36},
number = {2},
pages = {122--126},
doi = {10.2478/rjc-2026-0006}
}