EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Validation of a consumer-grade wearable activity tracker for sleep measurement in Vietnamese patients

Toan Thanh Le, Son Trung Huynh, Xuan-Hieu Thi Nguyen, Vinh Nhu Nguyen, An Le Pham

MedPharmRes · 2025

DOI: 10.32895/mpr.25.00033 ↗

Kurz gefasst

Fachartikel in der Zeitschrift MedPharmRes, 2025. Verfasst von Toan Thanh Le und 4 weiteren Autor:innen. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The increasing use of wearable activity trackers (WAT) for home-based sleep assessment has raised necessity to clarify their accuracy, particularly in resource-limited settings. This study aimed to validate WAT by polysomnography (PSG) for measuring key sleep parameters—including total sleep time (TST), sleep efficiency (SE), wake after sleep onset (WASO), sleep onset latency (SOL), and sleep stage distribution—in a Vietnamese clinical population, with implications for primary care applications. This cross-sectional study was conducted at the University Medical Center-Ho Chi Minh City, Vietnam, from December 2023 to July 2024. Sleep data were collected from 47 patients undergoing overnight PSG while simultaneously wearing a WAT. Sensitivity, specificity, and accuracy in detecting sleep versus wakefulness were assessed using epoch-by-epoch comparisons. Bland-Altman analysis was used to evaluate the agreement between WAT and PSG measurements, with mean differences and limits of agreement calculated for each sleep parameter. The WAT demonstrated high sensitivity (93%) but low specificity (44%) and an accuracy of 79% in identifying sleep versus wakefulness when compared to PSG. No significant differences were found between the two devices in measuring TST , SE, SOL, and sleep stages. However, the WAT significantly underestimated WASO compared to PSG (p=0.011). The results are promising, but further confirmation in larger studies is required to confirm the utility of WAT in primary care settings in Vietnam.

Zitieren

APA

Le, T. T., Huynh, S. T., Nguyen, X. T., Nguyen, V. N., & Pham, A. L. (2025). Validation of a consumer-grade wearable activity tracker for sleep measurement in Vietnamese patients. MedPharmRes. https://doi.org/10.32895/mpr.25.00033

Vancouver

Le TT, Huynh ST, Nguyen XT, Nguyen VN, Pham AL. Validation of a consumer-grade wearable activity tracker for sleep measurement in Vietnamese patients. MedPharmRes. 2025. doi:10.32895/mpr.25.00033

BibTeX
@article{Le2025,
  author = {Le, Toan Thanh and Huynh, Son Trung and Nguyen, Xuan-Hieu Thi and Nguyen, Vinh Nhu and Pham, An Le},
  title = {Validation of a consumer-grade wearable activity tracker for sleep measurement in Vietnamese patients},
  journal = {MedPharmRes},
  year = {2025},
  doi = {10.32895/mpr.25.00033}
}
Kostenlos starten →