EUVIMEDEUVIMED entdecken
Crossref

Decentralized Control Strategy for Balancing Transient Synchronization Support and Reducing Power-Angle Excursions in Multi-GFL Converter Systems

Yanxue Li, Yaqi Ding

Energy Engineering · 2026 · 1-10

DOI: 10.32604/ee.2026.090230 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energy Engineering, 2026. Verfasst von Yanxue Li und 1 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

: Renewable energy plants equipped with energy storage and connected to a local grid can be represented as parallel multi-converter systems, whose transient synchronization behavior directly affects secure operation. This paper proposes a decentralized control strategy for balancing transient synchronization support among unequal-rated grid-following converters and reducing their transient power-angle deviations. A transient mathematical model and a synchronous-generator-analogous synchronization model are first established. For a fixed operating and control mode, and under explicitly stated equilibrium-existence, positive-inertia, angular-domain, and integrated-damping-sign assumptions, a Lyapunov energy function is used to construct a compact positively invariant sublevel set for the reduced dominant-critical-mode model. Building on local Phase-Locked Loop-frequency-deviation current feedback, a rating-aware inverse-rating allocation of the current-compensation coefficients is developed. When converter current limits scale with rating and feeder parameters and normalized frequency excursions are comparable, the allocation approximately equalizes the absolute incremental synchronization support. Under identical operating and disturbance conditions, the maximum transient power-angle deviation Δ δ k,max is adopted as the primary quantitative index for evaluating transient synchronization stability capability, while the maximum angular-frequency deviation Δ𝜔 k,max is used as an auxiliary response index. A smaller Δ δ k,max indicates that the phase trajectory remains closer to its stable equilibrium in the comparative test. MATLAB/Simulink simulations with a no-compensation baseline and alternative coefficient allocations show reductions in the primary power-angle index and the auxiliary angular-frequency index under the tested voltage sag.

Zitieren

APA

Li, Y., & Ding, Y. (2026). Decentralized Control Strategy for Balancing Transient Synchronization Support and Reducing Power-Angle Excursions in Multi-GFL Converter Systems. Energy Engineering, 0(0), 1-10. https://doi.org/10.32604/ee.2026.090230

Vancouver

Li Y, Ding Y. Decentralized Control Strategy for Balancing Transient Synchronization Support and Reducing Power-Angle Excursions in Multi-GFL Converter Systems. Energy Engineering. 2026;0(0):1-10. doi:10.32604/ee.2026.090230

BibTeX
@article{Li2026,
  author = {Li, Yanxue and Ding, Yaqi},
  title = {Decentralized Control Strategy for Balancing Transient Synchronization Support and Reducing Power-Angle Excursions in Multi-GFL Converter Systems},
  journal = {Energy Engineering},
  year = {2026},
  volume = {0},
  number = {0},
  pages = {1--10},
  doi = {10.32604/ee.2026.090230}
}
Kostenlos starten →