Transient Synchronization Stability Control Strategy for Virtual Synchronous Converter Based on Phase Difference Locking

Jie Zhang, Si Yang, Kesheng Wang, Zhihao Wang, Weiyu Bao, Yunhai Lü, Hao Ding

Technologies · 04.03.2026 · 14 (3) · 159

DOI: 10.3390/technologies14030159 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Technologies, online erschienen am 04.03.2026. Verfasst von Jie Zhang und 6 weiteren Autor:innen. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Science and Technology Project of State Grid Shandong Electric Power Company.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

With the increasing penetration of renewable energy sources, power systems require more grid-forming converters. Grid-forming converters with virtual synchronous generator control have transient stability problems similar to those of synchronous machines. However, the active power reference, frequency, and phase in virtual synchronous generators are artificially constructed and can be changed fast. This provides new approaches to improve the transient synchronization stability. Most existing virtual synchronous generator controls generate the internal voltage phase by integrating the frequency, resulting in limited control capability, which makes it hard to stop power angle divergence during deep voltage sags. This paper proposes a transient synchronization stability control strategy based on phase difference locking. Under deep voltage sags, the phase difference between the internal voltage and the terminal voltage is locked to prevent divergence of the power angle, while under shallow sags, the virtual synchronous generator control is retained to maintain active power support. Moreover, a smooth post-fault transition is ensured. The proposed strategy achieves stability and support functions in single converter and multi-node systems. In the single converter test, the maximum frequency deviation of the converter during the transient process decreased from 0.043 p.u. to 0.009 p.u. In the 39-bus test under deep voltage sag conditions, the maximum frequency deviation of the converters during the transient process was reduced from 0.214 p.u. and 0.109 p.u. to 0.016 p.u. and 0.027 p.u., respectively.

Förderung

  • Science and Technology Project of State Grid Shandong Electric Power Company

Zitieren

APA

Zhang, J., Yang, S., Wang, K., Wang, Z., Bao, W., Lü, Y., & Ding, H. (2026). Transient Synchronization Stability Control Strategy for Virtual Synchronous Converter Based on Phase Difference Locking. Technologies, 14(3), 159. https://doi.org/10.3390/technologies14030159

Vancouver

Zhang J, Yang S, Wang K, Wang Z, Bao W, Lü Y, et al. Transient Synchronization Stability Control Strategy for Virtual Synchronous Converter Based on Phase Difference Locking. Technologies. 2026;14(3):159. doi:10.3390/technologies14030159

BibTeX
@article{Zhang2026,
  author = {Zhang, Jie and Yang, Si and Wang, Kesheng and Wang, Zhihao and Bao, Weiyu and Lü, Yunhai and Ding, Hao},
  title = {Transient Synchronization Stability Control Strategy for Virtual Synchronous Converter Based on Phase Difference Locking},
  journal = {Technologies},
  year = {2026},
  volume = {14},
  number = {3},
  pages = {159},
  doi = {10.3390/technologies14030159}
}
Kostenlos starten →