EUVIMEDEUVIMED entdecken
Crossref

Feasibility study of YSO/SiPM based detectors for virtual monochromatic image synthesis

Du Zhang, Bin Wu, Daoming Xi, Rui Chen, Peng Xiao, Qingguo Xie

Journal of X-Ray Science and Technology · 2024

DOI: 10.3233/xst-240039 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of X-Ray Science and Technology, 2024. Verfasst von Du Zhang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electronic Engineering and Information Science, University of Science and Technology of China, Hefei, China. Hauptthemen laut MEDLINE: Feasibility Studies, Phantoms, Imaging, Tomography, X-Ray Computed. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 53 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: The development of photon-counting CT systems has focused on semiconductor detectors like cadmium zinc telluride (CZT) and cadmium telluride (CdTe). However, these detectors face high costs and charge-sharing issues, distorting the energy spectrum. Indirect detection using Yttrium Orthosilicate (YSO) scintillators with silicon photomultiplier (SiPM) offers a cost-effective alternative with high detection efficiency, low dark count rate, and high sensor gain. OBJECTIVE: This work aims to demonstrate the feasibility of the YSO/SiPM detector (DexScanner L103) based on the Multi-Voltage Threshold (MVT) sampling method as a photon-counting CT detector by evaluating the synthesis error of virtual monochromatic images. METHODS: In this study, we developed a proof-of-concept benchtop photon-counting CT system, and employed a direct method for empirical virtual monochromatic image synthesis (EVMIS) by polynomial fitting under the principle of least square deviation without X-ray spectral information. The accuracy of the empirical energy calibration techniques was evaluated by comparing the reconstructed and actual attenuation coefficients of calibration and test materials using mean relative error (MRE) and mean square error (MSE). RESULTS: In dual-material imaging experiments, the overall average synthesis error for three monoenergetic images of distinct materials is 2.53% ±2.43%. Similarly, in K-edge imaging experiments encompassing four materials, the overall average synthesis error for three monoenergetic images is 4.04% ±2.63%. In rat biological soft-tissue imaging experiments, we further predicted the densities of various rat tissues as follows: bone density is 1.41±0.07 g/cm3, adipose tissue density is 0.91±0.06 g/cm3, heart tissue density is 1.09±0.04 g/cm3, and lung tissue density is 0.32±0.07 g/cm3. Those results showed that the reconstructed virtual monochromatic images had good conformance for each material. CONCLUSION: This study indicates the SiPM-based photon-counting detector could be used for monochromatic image synthesis and is a promising method for developing spectral computed tomography systems.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Feasibility StudiesPhantoms, ImagingTomography, X-Ray ComputedAnimalsRatsSiliconYttriumPhotonsScintillation CountingEquipment Design

Stichwörter der Autor:innen

Multi-voltage thresholdphoton-counting CTvirtual monochromatic image

Substanzen

SiliconYttrium

Autor:innen und Institutionen

  • Department of Electronic Engineering and Information Science, University of Science and Technology of China, Hefei, China.
  • Institute of Artificial Intelligence, Hefei Comprehensive National Science Center, Hefei, China.
  • The Raymeasure Medical Technology Co., Ltd., Suzhou, China.
  • Wuhan National Laboratory for Optoelectronics, Wuhan, China.

Zitieren

APA

Zhang, D., Wu, B., Xi, D., Chen, R., Xiao, P., & Xie, Q. (2024). Feasibility study of YSO/SiPM based detectors for virtual monochromatic image synthesis. Journal of X-Ray Science and Technology. https://doi.org/10.3233/xst-240039

Vancouver

Zhang D, Wu B, Xi D, Chen R, Xiao P, Xie Q. Feasibility study of YSO/SiPM based detectors for virtual monochromatic image synthesis. Journal of X-Ray Science and Technology. 2024. doi:10.3233/xst-240039

BibTeX
@article{Zhang2024,
  author = {Zhang, Du and Wu, Bin and Xi, Daoming and Chen, Rui and Xiao, Peng and Xie, Qingguo},
  title = {Feasibility study of YSO/SiPM based detectors for virtual monochromatic image synthesis},
  journal = {Journal of X-Ray Science and Technology},
  year = {2024},
  doi = {10.3233/xst-240039}
}
Kostenlos starten →