Proposing computed tomography diagnostic reference levels in Jordan: a national multicentre analysis
Physical and Engineering Sciences in Medicine · 2025
DOI: 10.1007/s13246-025-01667-2 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Physical and Engineering Sciences in Medicine, 2025. Verfasst von Abdel-Baset Bani Yaseen und 2 weiteren Autor:innen. Beteiligte Einrichtung: School of Clinical Sciences, Faculty of Health, Queensland University of Technology, Gardens Point Campus, Brisbane, QLD, 4000, Australia. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed. Die Arbeit nennt 28 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: The increased use of CT has raised concerns about patient radiation exposure. DRLs play a crucial role in optimising radiation dose while maintaining diagnostic quality. In Jordan, the absence of officially established national DRLs across a wide range of CT procedures may contributes to dose variability between healthcare facilities. METHODS: A multicentre, retrospective study was conducted across 10 hospitals in Jordan, involving 4310 adult patients (aged 18-96 years). Radiation dose metrics, including volume CTDIvol and DLP, were collected from PACS and RIS. The proposed national DRLs were derived from the 75th percentile of the distribution of median CTDIvol and DLP values from each hospital. Stepwise multiple regression analysis was performed to identify factors contributing to dose variability. RESULTS: Marked dose variations were observed across hospitals. Head routine non-contrast CT demonstrated the highest median CTDIvol (65 mGy) and DLP (1572 mGy·cm), while high-resolution chest CT exhibited the lowest (CTDIvol: 12 mGy; DLP: 230 mGy·cm). The product of mAs was identified as the most significant predictor of dose across all CT examinations. When compared to international DRLs, Jordan's CT dose levels were generally within acceptable ranges, though L-spine CT showed higher than average values. CONCLUSION: This study proposes the first national DRLs for 14 common CT examinations in Jordan, based on data collected from hospitals across the country. These benchmarks support dose optimisation, promote standardised protocols, and highlight the need for continuous radiographer training. Future initiatives should expand DRL development to paediatric populations and integrate dose tracking into national quality frameworks.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Clinical Sciences, Faculty of Health, Queensland University of Technology, Gardens Point Campus, Brisbane, QLD, 4000, Australia.
- Centre for Biomedical Technologies, Queensland University of Technology, Brisbane, QLD, 4000, Australia.
- Department of Medical Imaging, Faculty of Applied Medical Sciences, The Hashemite University, Zarqa, 13133, Jordan.
- School of Chemistry and Physics, Faculty of Science, Queensland University of Technology, Gardens Point Campus, Brisbane, QLD, 4000, Australia.
- School of Clinical Sciences, Faculty of Health, Queensland University of Technology, Gardens Point Campus, Brisbane, QLD, 4000, Australia. d3.fontanarosa@qut.edu.au.
- Centre for Biomedical Technologies, Queensland University of Technology, Brisbane, QLD, 4000, Australia. d3.fontanarosa@qut.edu.au.
Zitieren
APA
Bani Yaseen, A. B., Trapp, J., & Fontanarosa, D. (2025). Proposing computed tomography diagnostic reference levels in Jordan: a national multicentre analysis. Physical and Engineering Sciences in Medicine. https://doi.org/10.1007/s13246-025-01667-2
Vancouver
Bani Yaseen AB, Trapp J, Fontanarosa D. Proposing computed tomography diagnostic reference levels in Jordan: a national multicentre analysis. Physical and Engineering Sciences in Medicine. 2025. doi:10.1007/s13246-025-01667-2
BibTeX
@article{BaniYaseen2025,
author = {Bani Yaseen, Abdel-Baset and Trapp, Jamie and Fontanarosa, Davide},
title = {Proposing computed tomography diagnostic reference levels in Jordan: a national multicentre analysis},
journal = {Physical and Engineering Sciences in Medicine},
year = {2025},
doi = {10.1007/s13246-025-01667-2}
}
EUVIMED