Fachartikel in der Zeitschrift Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics, 2023. Verfasst von Huimin Yan und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Computer and Information Technology, Shanxi University, Taiyuan, Shanxi, China. Hauptthemen laut MEDLINE: Electric Power Supplies, Image Processing, Computer-Assisted. Die Arbeit nennt 30 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: An effective method for achieving low-dose CT is to keep the number of projection angles constant while reducing radiation dose at each angle. However, this leads to high-intensity noise in the reconstructed image, adversely affecting subsequent image processing, analysis, and diagnosis. OBJECTIVE: This paper proposes a novel Channel Graph Perception based U-shaped Transformer (CGP-Uformer) network, aiming to achieve high-performance denoising of low-dose CT images. METHODS: The network consists of convolutional feed-forward Transformer (ConvF-Transformer) blocks, a channel graph perception block (CGPB), and spatial cross-attention (SC-Attention) blocks. The ConvF-Transformer blocks enhance the ability of feature representation and information transmission through the CNN-based feed-forward network. The CGPB introduces Graph Convolutional Network (GCN) for Channel-to-Channel feature extraction, promoting the propagation of information across distinct channels and enabling inter-channel information interchange. The SC-Attention blocks reduce the semantic difference in feature fusion between the encoder and decoder by computing spatial cross-attention. RESULTS: By applying CGP-Uformer to process the 2016 NIH AAPM-Mayo LDCT challenge dataset, experiments show that the peak signal-to-noise ratio value is 35.56 and the structural similarity value is 0.9221. CONCLUSIONS: Compared to the other four representative denoising networks currently, this new network demonstrates superior denoising performance and better preservation of image details.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Electric Power SuppliesImage Processing, Computer-AssistedSignal-To-Noise RatioPerceptionTomography, X-Ray ComputedAlgorithms

Stichwörter der Autor:innen

Low-dose CTconvolutional neural networkdeep learninggraph convolutional networktransformer

Autor:innen und Institutionen

  • School of Computer and Information Technology, Shanxi University, Taiyuan, Shanxi, China.

Zitieren

APA

Yan, H., Fang, C., Liu, P., & Qiao, Z. (2023). CGP-Uformer: A low-dose CT image denoising Uformer based on channel graph perception. Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics. https://doi.org/10.3233/xst-230158

Vancouver

Yan H, Fang C, Liu P, Qiao Z. CGP-Uformer: A low-dose CT image denoising Uformer based on channel graph perception. Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics. 2023. doi:10.3233/xst-230158

BibTeX
@article{Yan2023,
  author = {Yan, Huimin and Fang, Chenyun and Liu, Peng and Qiao, Zhiwei},
  title = {CGP-Uformer: A low-dose CT image denoising Uformer based on channel graph perception},
  journal = {Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics},
  year = {2023},
  doi = {10.3233/xst-230158}
}
Kostenlos starten →