The value and accuracy of intracoronary electrocardiogram in the diagnosis of myocardial ischemia in coronary heart disease
Technology and Health Care · 2025
DOI: 10.3233/thc-240837 ↗Kurz gefasst
Fachartikel in der Zeitschrift Technology and Health Care, 2025. Verfasst von Shanwen Zhang und 6 weiteren Autor:innen. Hauptthemen laut MEDLINE: Electrocardiography, Myocardial Ischemia. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 14 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Although intracoronary electrocardiography (IC-ECG) offers direct electrophysiological insights into myocardial ischemia caused by insufficient coronary blood supply, compared to common diagnostic methods like electrocardiography (ECG), it lacks widespread adoption and robust clinical research. OBJECTIVE: To analyze the value and accuracy of intracoronary electrocardiogram in myocardial ischemia diagnosis in coronary heart disease patients. METHODS: Three hundred patients treated at our hospital were included in the study. Patients were categorized into non-ischemic group A (Fraction Flow Reserve [FFR] [Formula: see text] 0.8) and ischemic group B (FFR [Formula: see text] 0.75) based on FFR examination results. Both groups underwent IC-ECG examination. The ischemic group received percutaneous coronary intervention (PCI) treatment followed by another FFR examination, dividing them into non-ischemic subgroup B1 (FFR [Formula: see text] 0.8) and ischemic subgroup B2 (FFR [Formula: see text] 0.75). Both subgroups underwent IC-ECG examination. Receiver operating curves were constructed using FFR to assess the clinical utility of different IC-ECG parameters. RESULTS: Group A patients showed a significant decrease in ST-segment shift at J-point, ST-segment integral, T-peak, T-wave integral, and T-peak to end-time, while the Corrected Q-T interval (QTc-time) was significantly higher in the B group ([Formula: see text] 0.05). The parameters, including ST-segment shift at J-point, ST-segment integral, T-wave integral, T-peak, T-peak to end-time, and QTc-time, were found to have clinical significance in predicting the occurrence of myocardial ischemia ([Formula: see text] 0.05). CONCLUSION: Intracoronary electrocardiogram QT interval dispersion and Q-T peak (QTp) interval dispersion have a high diagnostic accuracy for myocardial ischemia in coronary heart disease.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Zitieren
APA
Zhang, S., Bao, Z., Liao, T., Pei, Z., Yang, S., Zhao, C., & Zhang, Y. (2025). The value and accuracy of intracoronary electrocardiogram in the diagnosis of myocardial ischemia in coronary heart disease. Technology and Health Care. https://doi.org/10.3233/thc-240837
Vancouver
Zhang S, Bao Z, Liao T, Pei Z, Yang S, Zhao C, et al. The value and accuracy of intracoronary electrocardiogram in the diagnosis of myocardial ischemia in coronary heart disease. Technology and Health Care. 2025. doi:10.3233/thc-240837
BibTeX
@article{Zhang2025,
author = {Zhang, Shanwen and Bao, Zhimin and Liao, Taotao and Pei, Zhenying and Yang, Shiyu and Zhao, Chunjiao and Zhang, Yuping},
title = {The value and accuracy of intracoronary electrocardiogram in the diagnosis of myocardial ischemia in coronary heart disease},
journal = {Technology and Health Care},
year = {2025},
doi = {10.3233/thc-240837}
}
EUVIMED