EUVIMEDEUVIMED entdecken
ValidierungsstudieOpen Access

Murray Law–Based Quantitative Flow Ratio Proficiency in Clinical Practice: Validating Routine Diagnostic Performance and Analyzing Learning Curve Thresholds

Dan Deng, Yue Feng iD, Min Zeng, Shuhui Chen iD, Haoran Qin, Yanxiu Chen iD, Lihua Li, Jianfang Zhu, Chen Wan, Hao Gao iD, Feng Liu, Dali Yi und 4 weitere

Journal of the American Heart Association · 2025

DOI: 10.1161/jaha.125.043773 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Journal of the American Heart Association, 2025. Verfasst von Dan Deng und 15 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Medicine, Center for Circadian Metabolism and Cardiovascular Disease, Southwest Hospital Army Medical University Chongqi…. Hauptthemen laut MEDLINE: Learning Curve, Fractional Flow Reserve, Myocardial, Coronary Angiography, Myocardial Ischemia. Die Arbeit nennt 21 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Although second‐generation Murray law–based quantitative flow ratio uses artificial intelligence–driven automation to improve angiography‐derived physiological assessment, the impact of operator learning curves on its diagnostic reliability in routine practice remains unclear.

Methods

Consecutive patients with suspected myocardial ischemia (May 2021 to July 2024) underwent online Murray law–based quantitative flow ratio computation from angiographic images, followed by fractional flow reserve measurement. Diagnostic accuracy was evaluated using receiver operating characteristic analysis. The number of vessels needed to achieve high performance (area under the curve [AUC] ≥0.90) was determined. Learning curves were assessed by sequentially expanding the data set starting from the first 11 vessels. First‐order AUC differences (ΔAUC n+1 =AUC n+1 −AUC n ) were calculated to assess the stabilization of diagnostic performance, where AUC n represents the area under the curve after analyzing the first n vessels.

Results

Murray law–based quantitative flow ratio showed excellent diagnostic accuracy: Vessel‐level AUC was 0.92 (95% CI, 0.89–0.94), and patient‐level AUC was 0.91 (95% CI, 0.88–0.94). An AUC ≥0.90 was achieved after analyzing 170 vessels, with continued improvement thereafter. Peak performance and stability were reached at 441 vessels, where incremental ΔAUC values showed no significant deviation from 0 (Mann–Whitney U test, P >0.05).

Conclusions

Operator experience significantly affects Murray law–based quantitative flow ratio accuracy. Analyzing at least 170 vessels ensures high reliability, with optimal performance achieved around 441 cases. Structured training is essential for integrating artificial intelligence–enhanced coronary physiology tools into clinical practice.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Learning CurveFractional Flow Reserve, MyocardialCoronary AngiographyMyocardial IschemiaCoronary Artery DiseaseHumansMaleFemaleMiddle AgedAgedReproducibility of ResultsROC CurveClinical Competence

Stichwörter der Autor:innen

Murray law–based quantitative flow ratiocoronary physiologydiagnostic accuracyoperator learning curve

Autor:innen und Institutionen

  • Department of Cardiovascular Medicine, Center for Circadian Metabolism and Cardiovascular Disease, Southwest Hospital Army Medical University Chongqing China.
  • Key Laboratory of Geriatric Cardiovascular and Cerebrovascular Disease Ministry of Education Chongqing China.
  • Department of Health Statistics Army Medical University Chongqing China.
  • Department of Mathematics Army Medical University Chongqing China.
  • Department of Medicine and Therapeutics, Faculty of Medicine The Chinese University of Hong Kong Hong Kong China.
  • Biomedical Instrument Institute, School of Biomedical Engineering Shanghai Jiao Tong University Shanghai China.

ORCID-Profile: Yue Feng, Shuhui Chen, Yanxiu Chen, Hao Gao, Wanchun Luo, Shengxian Tu, Zhihui Zhang

Zitieren

APA

Deng, D., Feng, Y., Zeng, M., Chen, S., Qin, H., Chen, Y., Li, L., Zhu, J., Wan, C., Gao, H., Liu, F., Yi, D., Luo, W., Hau, W. K., Tu, S., & Zhang, Z. (2025). Murray Law–Based Quantitative Flow Ratio Proficiency in Clinical Practice: Validating Routine Diagnostic Performance and Analyzing Learning Curve Thresholds. Journal of the American Heart Association. https://doi.org/10.1161/jaha.125.043773

Vancouver

Deng D, Feng Y, Zeng M, Chen S, Qin H, Chen Y, et al. Murray Law–Based Quantitative Flow Ratio Proficiency in Clinical Practice: Validating Routine Diagnostic Performance and Analyzing Learning Curve Thresholds. Journal of the American Heart Association. 2025. doi:10.1161/jaha.125.043773

BibTeX
@article{Deng2025,
  author = {Deng, Dan and Feng, Yue and Zeng, Min and Chen, Shuhui and Qin, Haoran and Chen, Yanxiu and Li, Lihua and Zhu, Jianfang and Wan, Chen and Gao, Hao and Liu, Feng and Yi, Dali and Luo, Wanchun and Hau, William Kongto and Tu, Shengxian and Zhang, Zhihui},
  title = {Murray Law–Based Quantitative Flow Ratio Proficiency in Clinical Practice: Validating Routine Diagnostic Performance and Analyzing Learning Curve Thresholds},
  journal = {Journal of the American Heart Association},
  year = {2025},
  doi = {10.1161/jaha.125.043773}
}
Kostenlos starten →