Kurz gefasst

Fachartikel in der Zeitschrift Technology and Health Care, erschienen am 12.07.2024. Verfasst von Qinghua Hu und 3 weiteren Autor:innen. Hauptthemen laut MEDLINE: Photoplethysmography, Algorithms, Signal-To-Noise Ratio, Signal Processing, Computer-Assisted. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 38 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Photoplethysmography (PPG) signals are sensitive to motion-induced interference, leading to the emergence of motion artifacts (MA) and baseline drift, which significantly affect the accuracy of PPG measurements. OBJECTIVE: The objective of our study is to effectively eliminate baseline drift and high-frequency noise from PPG signals, ensuring that the signal’s critical frequency components remain within the range of 1 ∼ 10 Hz. METHODS: This paper introduces a novel hybrid denoising method for PPG signals, integrating Variational Mode Decomposition (VMD) with an improved wavelet threshold function. The method initially employs VMD to decompose PPG signals into a set of narrowband intrinsic mode function (IMF) components, effectively removing low-frequency baseline drift. Subsequently, an improved wavelet thresholding algorithm is applied to eliminate high-frequency noise, resulting in denoised PPG signals. The effectiveness of the denoising method was rigorously assessed through a comprehensive validation process. It was tested on real-world PPG measurements, PPG signals generated by the Fluke ProSim™ 8 Vital Signs Simulator with synthesized noise, and extended to the MIMIC-III waveform database. RESULTS: The application of the improved threshold function let to a substantial 11.47% increase in signal-to-noise ratio (SNR) and an impressive 26.75% reduction in root mean square error (RMSE) compared to the soft threshold function. Furthermore, the hybrid denoising method improved SNR by 15.54% and reduced RMSE by 37.43% compared to the improved threshold function. CONCLUSION: This study proposes an effective PPG denoising algorithm based on VMD and an improved wavelet threshold function, capable of simultaneously eliminating low-frequency baseline drift and high-frequency noise in PPG signals while faithfully preserving their morphological characteristics. This advancement establishes the foundation for time-domain feature extraction and model development in the domain of PPG signal analysis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PhotoplethysmographyAlgorithmsSignal-To-Noise RatioSignal Processing, Computer-AssistedWavelet AnalysisHumansArtifacts

Stichwörter der Autor:innen

Variational mode decompositiondenoisingimproved wavelet thresholdingphotoplethysmography

Zitieren

APA

Hu, Q., Li, M., Jiang, L., & Liu, M. (2024). A hybrid denoising approach for PPG signals utilizing variational mode decomposition and improved wavelet thresholding. Technology and Health Care, 32(4), 2793-2814. https://doi.org/10.3233/thc-231996

Vancouver

Hu Q, Li M, Jiang L, Liu M. A hybrid denoising approach for PPG signals utilizing variational mode decomposition and improved wavelet thresholding. Technology and Health Care. 2024;32(4):2793-2814. doi:10.3233/thc-231996

BibTeX
@article{Hu2024,
  author = {Hu, Qinghua and Li, Min and Jiang, Linwen and Liu, Mei},
  title = {A hybrid denoising approach for PPG signals utilizing variational mode decomposition and improved wavelet thresholding},
  journal = {Technology and Health Care},
  year = {2024},
  volume = {32},
  number = {4},
  pages = {2793--2814},
  doi = {10.3233/thc-231996}
}
Kostenlos starten →