Kurz gefasst

Fachartikel in der Zeitschrift Physical and Engineering Sciences in Medicine, 2024. Verfasst von Xinhai Li und 2 weiteren Autor:innen. Beteiligte Einrichtung: College of Bioengineering, Chongqing University, Chongqing, 400030, China. Hauptthemen laut MEDLINE: Signal-To-Noise Ratio, Algorithms, Signal Processing, Computer-Assisted, Cardiography, Impedance. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 25 Literaturangaben. Gefördert von: Innovative Research Group Project of the National Natural Science Foundation of China, Chongqing Graduate Student Research Innovation Project.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Impedance cardiography (ICG) plays a crucial role in clinically evaluating cardiac systolic and diastolic functions, along with various other cardiac parameters. However, its accuracy heavily depends on precisely identifying feature points reflecting cardiac function. Moreover, traditional signal processing techniques used to mitigate random noise and breathing artifacts may inadvertently distort the amplitude and temporal characteristics of ICG signals. To address this issue, this study investigates a noise and artifact elimination method based on Improved Complete Ensemble Empirical Mode Decomposition with Adaptive Noise (ICEEMDAN) and Particle Swarm Optimization-based Variational Mode Decomposition Algorithm (PSO-VMD). The goal is to preserve the amplitude and temporal features of ICG signals to ensure accurate feature point extraction and computation of associated cardiac parameters. Comparative analysis with signal processing methods employing various wavelet families and Ensemble Empirical Mode Decomposition (EEMD) in ICG signal processing applications reveals that the proposed method achieves superior signal-to-noise ratio (SNR) and lower root-mean-square error (RMSE), while demonstrating enhanced correlation and waveform consistency with the original signal.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Signal-To-Noise RatioAlgorithmsSignal Processing, Computer-AssistedCardiography, ImpedanceHumansArtifactsWavelet Analysis

Stichwörter der Autor:innen

DenoisingFeaturesICEEMADANICGPSO-VMD

Autor:innen und Institutionen

  • College of Bioengineering, Chongqing University, Chongqing, 400030, China.
  • College of Bioengineering, Chongqing University, Chongqing, 400030, China. jizhong@cqu.edu.cn.
  • Key Laboratory of Bioarcheological Science and Technology Chongqing University, Ministry of Education, Chong Qing, China. jizhong@cqu.edu.cn.

Förderung

  • Innovative Research Group Project of the National Natural Science Foundation of China
  • Chongqing Graduate Student Research Innovation Project

Zitieren

APA

Li, X., Ni, R., & Ji, Z. (2024). ICG signal denoising based on ICEEMDAN and PSO-VMD methods. Physical and Engineering Sciences in Medicine. https://doi.org/10.1007/s13246-024-01467-0

Vancouver

Li X, Ni R, Ji Z. ICG signal denoising based on ICEEMDAN and PSO-VMD methods. Physical and Engineering Sciences in Medicine. 2024. doi:10.1007/s13246-024-01467-0

BibTeX
@article{Li2024,
  author = {Li, Xinhai and Ni, Runyu and Ji, Zhong},
  title = {ICG signal denoising based on ICEEMDAN and PSO-VMD methods},
  journal = {Physical and Engineering Sciences in Medicine},
  year = {2024},
  doi = {10.1007/s13246-024-01467-0}
}
Kostenlos starten →