EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Experimental study using phantom models of cerebral aneurysms and 4D-DSA to measure blood flow on 3D-color-coded images

Soichiro Fujimura, Yuma Yamanaka, Issei Kan, Masahiro Nagao, Katharina Otani, Kostadin Karagiozov, Koji Fukudome, Toshihiro Ishibashi, Hiroyuki Takao, Masahiro Motosuke, Makoto Yamamoto, Yuichi Murayama

Technology and Health Care · 2024

DOI: 10.3233/thc-231906 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Technology and Health Care, 2024. Verfasst von Soichiro Fujimura und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, Tokyo University of Science, Tokyo, Japan. Hauptthemen laut MEDLINE: Intracranial Aneurysm, Phantoms, Imaging, Angiography, Digital Subtraction, Imaging, Three-Dimensional. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: The current 3D-iFlow application can only measure the arrival time of contrast media through intensity values. If the flow rate could be estimated by 3D-iFlow, patient-specific hemodynamics could be determined within the scope of normal diagnostic management, eliminating the need for additional resources for blood flow rate estimation. OBJECTIVE: The aim of this study is to develop and validate a method for measuring the flow rate by data obtained from 3D-iFlow images – a prototype application in Four-dimensional digital subtraction angiography (4D-DSA). METHODS: Using phantom model and experimental circuit with circulating glycerin solution, an equation for the relationship between contrast media intensity and flow rate was developed. Applying the equation to the aneurysm phantom models, the derived flow rate was evaluated. RESULTS: The average errors between the derived flow rate and setting flow rate became larger when the glycerin flow and the X-rays from the X-ray tube of the angiography system were parallel to each other or when the measurement point included overlaps with other contrast enhanced areas. CONCLUSION: Although the error increases dependent on the imaging direction and overlap of contrast enhanced area, the developed equation can estimate the flow rate using the image intensity value measured on 3D-iFlow based on 4D-DSA.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Intracranial AneurysmPhantoms, ImagingAngiography, Digital SubtractionImaging, Three-DimensionalHumansBlood Flow VelocityContrast MediaCerebrovascular Circulation

Stichwörter der Autor:innen

Aneurysmfour-dimensional digital subtraction angiographyhemodynamics

Substanzen

Contrast Media

Autor:innen und Institutionen

  • Department of Mechanical Engineering, Tokyo University of Science, Tokyo, Japan.
  • Division of Innovation for Medical Information Technology, The Jikei University School of Medicine, Tokyo, Japan.
  • Graduate School of Mechanical Engineering, Tokyo University of Science, Tokyo, Japan.
  • Department of Neurosurgery, The Jikei University School of Medicine, Tokyo, Japan.
  • Siemens Healthcare K.K., Tokyo, Japan.
  • Department of Mechanical Engineering, Kanazawa Institute of Technology, Ishikawa, Japan.

Zitieren

APA

Fujimura, S., Yamanaka, Y., Kan, I., Nagao, M., Otani, K., Karagiozov, K., Fukudome, K., Ishibashi, T., Takao, H., Motosuke, M., Yamamoto, M., & Murayama, Y. (2024). Experimental study using phantom models of cerebral aneurysms and 4D-DSA to measure blood flow on 3D-color-coded images. Technology and Health Care. https://doi.org/10.3233/thc-231906

Vancouver

Fujimura S, Yamanaka Y, Kan I, Nagao M, Otani K, Karagiozov K, et al. Experimental study using phantom models of cerebral aneurysms and 4D-DSA to measure blood flow on 3D-color-coded images. Technology and Health Care. 2024. doi:10.3233/thc-231906

BibTeX
@article{Fujimura2024,
  author = {Fujimura, Soichiro and Yamanaka, Yuma and Kan, Issei and Nagao, Masahiro and Otani, Katharina and Karagiozov, Kostadin and Fukudome, Koji and Ishibashi, Toshihiro and Takao, Hiroyuki and Motosuke, Masahiro and Yamamoto, Makoto and Murayama, Yuichi},
  title = {Experimental study using phantom models of cerebral aneurysms and 4D-DSA to measure blood flow on 3D-color-coded images},
  journal = {Technology and Health Care},
  year = {2024},
  doi = {10.3233/thc-231906}
}
Kostenlos starten →