EUVIMEDEUVIMED entdecken
Crossref

Fluoroscopy-based robotic assistance for total hip arthroplasty improves acetabular cup placement accuracy for obese patients compared to the manual, fluoroscopic- assisted technique

Christian B Ong, Graham B J Buchan, Christian J Hecht Ii, Daniel O Kendoff, Yasuhiro Homma, Atul F Kamath

Technology and Health Care · 2024

DOI: 10.3233/thc-231127 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Technology and Health Care, 2024. Verfasst von Christian B Ong und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Orthopaedic and Rheumatologic Institute, Cleveland Clinic Foundation, Cleveland, OH, USA. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Obesity, Robotic Surgical Procedures. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 30 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Patient obesity is a risk factor for poor acetabular cup positioning in total hip arthroplasty (THA). OBJECTIVE: To assess the impact of using a novel, fluoroscopy-based robotic THA system on acetabular cup placement in obese versus non-obese patients. METHODS: A review of 105 consecutive manual unassisted (mTHA) (47 Obese/58 Non-obese) and 102 robotic-assisted (RA-THA) (50 Obese/52 Non-obese) primary, direct anterior approach THA procedures was conducted. All cases were performed by a single surgeon, for a pre-operative diagnosis of osteoarthritis, avascular necrosis, or rheumatoid arthritis. Obesity was defined as a Body Mass Index (BMI) ⩾ 30 kg/m 2 . Outcomes included acetabular cup inclination and anteversion, and the proportion of cups within the Lewinnek safe-zone. RESULTS: Obese patients in the mTHA cohort had larger cup inclination angles on average compared to non-obese patients (44.82 ∘ ± 6.51 vs. 41.39 ∘ ± 6.75; p = 0.009). Obese mTHA patients were less likely to have cup placement within the Lewinnek zone compared to non-obese mTHA patients (0.48 vs. 0.67; p = 0.027). Obesity had no effect on the accuracy of RA-THA. CONCLUSION: Obesity affects the placement of the acetabular component in manual THA. The novel, fluoroscopy-based robotic THA system in this study demonstrated accurate cup placement regardless of obesity status.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, HipObesityRobotic Surgical ProceduresHumansFluoroscopyMaleFemaleMiddle AgedAgedAcetabulumBody Mass IndexRetrospective Studies

Stichwörter der Autor:innen

Arthroplastyacetabulumhipobesityrobotic-assisted surgery

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery, Orthopaedic and Rheumatologic Institute, Cleveland Clinic Foundation, Cleveland, OH, USA.
  • Chefarzt Zentrum für Orthopädie und Unfallchirurgie, HELIOS Kliniken Berlin-Buch, Berlin, Germany.
  • Department of Medicine for Orthopaedics and Motor Organs, Juntendo University Graduate School of Medicine, Tokyo, Japan.
  • Department of Orthopaedics, Faculty of Medicine, Juntendo University, Tokyo, Japan.

Zitieren

APA

Ong, C. B., Buchan, G. B. J., Hecht Ii, C. J., Kendoff, D. O., Homma, Y., & Kamath, A. F. (2024). Fluoroscopy-based robotic assistance for total hip arthroplasty improves acetabular cup placement accuracy for obese patients compared to the manual, fluoroscopic- assisted technique. Technology and Health Care. https://doi.org/10.3233/thc-231127

Vancouver

Ong CB, Buchan GBJ, Hecht Ii CJ, Kendoff DO, Homma Y, Kamath AF. Fluoroscopy-based robotic assistance for total hip arthroplasty improves acetabular cup placement accuracy for obese patients compared to the manual, fluoroscopic- assisted technique. Technology and Health Care. 2024. doi:10.3233/thc-231127

BibTeX
@article{Ong2024,
  author = {Ong, Christian B and Buchan, Graham B J and Hecht Ii, Christian J and Kendoff, Daniel O and Homma, Yasuhiro and Kamath, Atul F},
  title = {Fluoroscopy-based robotic assistance for total hip arthroplasty improves acetabular cup placement accuracy for obese patients compared to the manual, fluoroscopic- assisted technique},
  journal = {Technology and Health Care},
  year = {2024},
  doi = {10.3233/thc-231127}
}
Kostenlos starten →