Robotic arm-assisted total hip arthroplasty enables accurate cup orientation and positioning in obese patients with osteoarthritis secondary to developmental dysplasia of the hip: a propensity score-matched comparative study
HIP International · 2026
DOI: 10.1177/11207000251378086 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift HIP International, 2026. Verfasst von Yasuyuki Omichi und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics, Tokushima Municipal Hospital, 2-34 Kitajousanjima, Tokushima City, Tokushima 770-0812, Japan. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Obesity, Robotic Surgical Procedures, Osteoarthritis, Hip. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 34 Literaturangaben.
Abstract (Originalsprache)
Introduction
This study evaluated the accuracy of cup placement by the robotic arm-assisted system (Mako) in obese patients with developmental dysplasia of the hip (DDH).
Methods
This retrospective single-centre study included 923 consecutive hips with primary robotic arm-assisted total hip arthroplasty (THA). After propensity score-matching, 80 hips with DDH each were selected for the obese group and non-obese group. Postoperative cup orientation and positioning were assessed by superimposition of a 3-dimensional cup template, using postoperative computed tomography images with pelvic coordinates matching the preoperative planning.
Results
The absolute error of cup inclination and anteversion was comparable between the obese and non-obese groups (1.2 ± 1.0° vs. 1.2 ± 1.0° and 1.4 ± 1.0° vs. 1.6 ± 1.2°, respectively). The absolute error of the transverse, sagittal, and longitudinal axes between the obese and non-obese groups were 1.0 ± 0.9 mm vs. 1.4 ± 1.0 mm, 1.5 ± 1.0 mm vs. 1.3 ± 1.8 mm, and 1.4 ± 1.2 mm vs. 1.3 ± 0.9 mm ( p = 0.02, p = 0.89, and p = 0.12, respectively). There was no significant difference in cup orientation or positioning in the obese group, regardless of body mass index.
Conclusions
Robotic arm-assisted THA enables accurate cup placement even in obese patients with DDH.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedics, Tokushima Municipal Hospital, 2-34 Kitajousanjima, Tokushima City, Tokushima 770-0812, Japan.
- Department of Rehabilitation Medicine, Tokushima Municipal Hospital, 2-34 Kitajousanjima, Tokushima City, Tokushima 770-0812, Japan.
- Department of Orthopaedics, Institute of Biomedical Sciences, Tokushima University, 3-18-15 Kuramoto, Tokushima City, Tokushima 770-8503, Japan.
ORCID-Profile: Yasuyuki Omichi
Zitieren
APA
Omichi, Y., Goto, T., Yoshida, G., Nakayama, Y., Takai, M., Sato, R., Enishi, T., Sairyo, K., & Nakano, S. (2026). Robotic arm-assisted total hip arthroplasty enables accurate cup orientation and positioning in obese patients with osteoarthritis secondary to developmental dysplasia of the hip: a propensity score-matched comparative study. HIP International. https://doi.org/10.1177/11207000251378086
Vancouver
Omichi Y, Goto T, Yoshida G, Nakayama Y, Takai M, Sato R, et al. Robotic arm-assisted total hip arthroplasty enables accurate cup orientation and positioning in obese patients with osteoarthritis secondary to developmental dysplasia of the hip: a propensity score-matched comparative study. HIP International. 2026. doi:10.1177/11207000251378086
BibTeX
@article{Omichi2026,
author = {Omichi, Yasuyuki and Goto, Tomohiro and Yoshida, Gakuto and Nakayama, Yusaku and Takai, Michihiro and Sato, Ryosuke and Enishi, Tetsuya and Sairyo, Koichi and Nakano, Shunji},
title = {Robotic arm-assisted total hip arthroplasty enables accurate cup orientation and positioning in obese patients with osteoarthritis secondary to developmental dysplasia of the hip: a propensity score-matched comparative study},
journal = {HIP International},
year = {2026},
doi = {10.1177/11207000251378086}
}