EUVIMEDEUVIMED entdecken
Vergleichsstudie

Fluoroscopy-based robotics in total hip arthroplasty mitigates laterality-based differences in acetabular cup placement when compared to the manual, fluoroscopic- assisted technique

Christian B Ong, Graham B J Buchan, Christian J Hecht Ii, Yasuhiro Homma, Daniel J Harmon, Daniel O Kendoff, Joshua Petterwood, Atul F Kamath

Technology and Health Care · 2024

DOI: 10.3233/thc-231126 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Technology and Health Care, 2024. Verfasst von Christian B Ong und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Orthopaedic and Rheumatologic Institute, Cleveland Clinic Foundation, Cleveland, OH, USA. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Robotic Surgical Procedures, Acetabulum. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 25 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Robotic assistance in total hip arthroplasty (RA-THA) has been shown to minimize laterality-based differences in acetabular cup positioning. OBJECTIVE: To determine if the use of a novel, fluoroscopy-based RA-THA system mitigates differences in acetabular cup placement between left (L) and right (R) side hip procedures, when compared to manual, fluoroscopic-assisted technique. METHODS: We conducted a retrospective review of 106 consecutive mTHA (40 L/66 R) and 102 RA-THA (48 L/54 R) primary direct anterior approach procedures. All cases were performed by a single right-hand-dominant surgeon, for a pre-operative diagnosis of osteoarthritis, avascular necrosis, or rheumatoid arthritis. Outcomes included acetabular cup inclination and anteversion, and the proportion of cups within the Lewinnek safe-zone. RESULTS: The average inclination of mTHA L cases was smaller than that of mTHA R cases (41.10 ∘ ± 7.38 vs. 43.97 ∘ ± 6.27; p = 0.04). For RA-THA, L and R cup angles were similar. There were fewer overall mTHA hips within the Lewinnek safe-zone compared to RA-THA (0.59 vs. 0.78; p = 0.003), as well as fewer mTHA R cases than RA-THA R cases (0.59 vs. 0.80; p = 0.03) within safe zone. CONCLUSION: Use of a novel, fluoroscopy-based robotic system mitigates laterality-based differences in acetabular cup placement that were observed in a manual, fluoroscopic-assisted cohort.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, HipRobotic Surgical ProceduresAcetabulumHumansFluoroscopyRetrospective StudiesFemaleMaleMiddle AgedAged

Stichwörter der Autor:innen

Arthroplastyacetabulumfunctional lateralityhiprobotic-assisted surgery

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery, Orthopaedic and Rheumatologic Institute, Cleveland Clinic Foundation, Cleveland, OH, USA.
  • Department of Medicine for Orthopaedics and Motor Organs, Juntendo University Graduate School of Medicine, Tokyo, Japan.
  • Department of Orthopaedics, Faculty of Medicine, Juntendo University, Tokyo, Japan.
  • Chefarzt Zentrum für Orthopädie und Unfallchirurgie, HELIOS Kliniken Berlin-Buch, Berlin, Germany.
  • Department of Orthopaedics, Royal Hobart Hospital, Hobart, TAS, Australia.
  • Department of Orthopaedics, Calvary Hospital, Hobart, TAS, Australia.

Zitieren

APA

Ong, C. B., Buchan, G. B. J., Hecht Ii, C. J., Homma, Y., Harmon, D. J., Kendoff, D. O., Petterwood, J., & Kamath, A. F. (2024). Fluoroscopy-based robotics in total hip arthroplasty mitigates laterality-based differences in acetabular cup placement when compared to the manual, fluoroscopic- assisted technique. Technology and Health Care. https://doi.org/10.3233/thc-231126

Vancouver

Ong CB, Buchan GBJ, Hecht Ii CJ, Homma Y, Harmon DJ, Kendoff DO, et al. Fluoroscopy-based robotics in total hip arthroplasty mitigates laterality-based differences in acetabular cup placement when compared to the manual, fluoroscopic- assisted technique. Technology and Health Care. 2024. doi:10.3233/thc-231126

BibTeX
@article{Ong2024,
  author = {Ong, Christian B and Buchan, Graham B J and Hecht Ii, Christian J and Homma, Yasuhiro and Harmon, Daniel J and Kendoff, Daniel O and Petterwood, Joshua and Kamath, Atul F},
  title = {Fluoroscopy-based robotics in total hip arthroplasty mitigates laterality-based differences in acetabular cup placement when compared to the manual, fluoroscopic- assisted technique},
  journal = {Technology and Health Care},
  year = {2024},
  doi = {10.3233/thc-231126}
}
Kostenlos starten →