Ultrasound-based horizontal ranging in the localization of fetal conus medullaris

Xiuping Liu, Ping Li, Yuemin Yang, Cheng Tian

Technology and Health Care · 2024

DOI: 10.3233/thc-230332 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Technology and Health Care, 2024. Verfasst von Xiuping Liu und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Obstetrics and Gynecology, Hebei Medical University Third Hospital, Shijiazhuang, Hebei, China. Hauptthemen laut MEDLINE: Ultrasonography, Prenatal, Spinal Cord, Gestational Age. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Currently, there are a variety of methods for ultrasound to localize the conus medullaris. A concern is that measured values can be influenced by variations in spinal flexion and extension. OBJECTIVE: To overcome this limitation, the present study measures the horizontal distance (HD) between the end of the conus medullaris and the caudal edge of last vertebral body ossification in normal fetus at different gestational weeks, and analyzes the relationship between the measured value and fetal growth, as well as the utility of these measurements in assessing the position of the conus medullaris. METHODS: A total of 655 fetuses at gestational weeks 18–40, who underwent routine prenatal ultrasound, were selected in the study. We measured the distance between the end of the cone of the fetal spinal cord and the caudal end of the final vertebral ossification center (Distance1, D1), the distance between the end of the spinal cord cone and the intersection of the extension of D1 with the caudal skin (Distance2, D2), and HD. We analyzed the correlation between the measurements and gestational weeks, established normal reference values, the ratio of D1, D2 and HD to the commonly used growth parameters was calculated. The ratios of D1, D2, HD and the application value of each ratio phase were analyzed, and the reliability analysis of repeated measurement results among physicians was performed. RESULTS: D1, D2 and HD exhibited strong linear correlations with gestational weeks. Among the ratios of D1, D2 and HD to common growth parameters, D2/FL stabilized after 20 weeks of gestation and consistently exceeded 1. Repeatability tests between D1, D2 and HD showed good reliability ( P > 0.05). CONCLUSION: D1, D2 and HD are significantly correlated with gestational age. Horizontal distance measurement can effectively determine the position of fetal conus medullaris, enabling rapid prenatal evaluation of low position of conus medullaris and excluding the possibility of tethered cord.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Ultrasonography, PrenatalSpinal CordGestational AgeHumansFemalePregnancyAdultReproducibility of ResultsFetal DevelopmentReference Values

Stichwörter der Autor:innen

Fetusconus medullaristethered spinal cordultrasonic examination

Autor:innen und Institutionen

  • Department of Obstetrics and Gynecology, Hebei Medical University Third Hospital, Shijiazhuang, Hebei, China.
  • Department of Ultrasound, Hebei Medical University Third Hospital, Shijiazhuang, Hebei, China.

Zitieren

APA

Liu, X., Li, P., Yang, Y., & Tian, C. (2024). Ultrasound-based horizontal ranging in the localization of fetal conus medullaris. Technology and Health Care. https://doi.org/10.3233/thc-230332

Vancouver

Liu X, Li P, Yang Y, Tian C. Ultrasound-based horizontal ranging in the localization of fetal conus medullaris. Technology and Health Care. 2024. doi:10.3233/thc-230332

BibTeX
@article{Liu2024,
  author = {Liu, Xiuping and Li, Ping and Yang, Yuemin and Tian, Cheng},
  title = {Ultrasound-based horizontal ranging in the localization of fetal conus medullaris},
  journal = {Technology and Health Care},
  year = {2024},
  doi = {10.3233/thc-230332}
}
Kostenlos starten →