Reference Values for Fetal Cardiac Dimensions, Volumes, Ventricular Function and Left Ventricular Longitudinal Strain Using Doppler Ultrasound Gated Cardiac Magnetic Resonance Imaging in Healthy Third Trimester Fetuses

Prashant K Minocha iD, Erin K Englund iD, Richard M Friesen, Takashi Fujiwara iD, Sarah A Smith, Mariana L Meyers, Lorna P Browne, Alex J Barker iD

Journal of Magnetic Resonance Imaging · 2024

DOI: 10.1002/jmri.29077 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Magnetic Resonance Imaging, 2024. Verfasst von Prashant K Minocha und 7 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiology, Heart Institute, Children's Hospital Colorado, University of Colorado School of Medicine, Aurora, Colorado, USA. Hauptthemen laut MEDLINE: Pregnancy Trimester, Third, Fetal Heart, Heart Ventricles, Ventricular Function, Left. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Colorado Fetal Care Center, NCATS NIH HHS, Colorado Center for Translational Science Institute Translational Methods.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Recent advances in hardware and software permit the use of cardiac MRI of late gestation fetuses, however there is a paucity of MRI‐based reference values.

Purpose

To provide initial data on fetal cardiac MRI‐derived cardiac dimensions, volumes, ventricular function, and left ventricular longitudinal strain in healthy developing fetuses >30 weeks gestational age. Study Type Prospective. Population Twenty‐five third trimester (34 ± 1 weeks, range of 32–37 weeks gestation) women with healthy developing fetuses. Field Strength/Sequence Studies were performed at 1.5 T and 3 T. Cardiac synchronization was achieved with a Doppler ultrasound device. The protocol included T2 single shot turbo spin echo stacks for fetal weight and ultrasound probe positioning, and multiplanar multi‐slice cine balanced steady state free precession gradient echo sequences. Assessment Primary analyses were performed by a single observer. Weight indexed right ventricular (RV) and left ventricular (LV) volumes and function were calculated from short axis (SAX) stacks. Cardiac dimensions were calculated from the four‐chamber and SAX stacks. Single plane LV longitudinal strain was calculated from the four‐chamber stack. Interobserver variability was assessed in 10 participants. Cardiac MRI values were compared against available published normative fetal echocardiogram data using z ‐scores. Statistical Tests Mean and SDs were calculated for baseline maternal/fetal demographics, cardiac dimensions, volumes, ventricular function, and left ventricular longitudinal strain. Bland–Altman and intraclass correlation coefficient analysis was performed to test interobserver variability.

Results

The mean gestational age was 34 ± 1.4 weeks. The mean RV and LV end diastolic volumes were 3.1 ± 0.6 mL/kg and 2.4 ± 0.5 mL/kg respectively. The mean RV cardiac output was 198 ± 49 mL/min/kg while the mean LV cardiac output was 173 ± 43 mL/min/kg. Data Conclusion This paper reports initial reference values obtained by cardiac MRI in healthy developing third trimester fetuses. MRI generally resulted in slightly larger indexed values (by z ‐score) compared to reports in literature using fetal echocardiography. Evidence level 1 Technical Efficacy Stage 2

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pregnancy Trimester, ThirdFetal HeartHeart VentriclesVentricular Function, LeftGestational AgeHumansFemalePregnancyReference ValuesProspective StudiesAdultMagnetic Resonance ImagingUltrasonography, PrenatalFetusObserver VariationReproducibility of ResultsMagnetic Resonance Imaging, Cine

Stichwörter der Autor:innen

cardiac dimensionsfetal cardiac MRIlongitudinal strainventricular functionventricular size

Autor:innen und Institutionen

  • Division of Cardiology, Heart Institute, Children's Hospital Colorado, University of Colorado School of Medicine, Aurora, Colorado, USA.
  • Department of Radiology, Section of Pediatric Radiology, Children's Hospital Colorado, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA.
  • Department of Bioengineering, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA.

ORCID-Profile: Prashant K Minocha, Erin K Englund, Takashi Fujiwara, Alex J Barker

Förderung

  • Colorado Fetal Care Center
  • NCATS NIH HHS
  • Colorado Center for Translational Science Institute Translational Methods

Zitieren

APA

Minocha, P. K., Englund, E. K., Friesen, R. M., Fujiwara, T., Smith, S. A., Meyers, M. L., Browne, L. P., & Barker, A. J. (2024). Reference Values for Fetal Cardiac Dimensions, Volumes, Ventricular Function and Left Ventricular Longitudinal Strain Using Doppler Ultrasound Gated Cardiac Magnetic Resonance Imaging in Healthy Third Trimester Fetuses. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.29077

Vancouver

Minocha PK, Englund EK, Friesen RM, Fujiwara T, Smith SA, Meyers ML, et al. Reference Values for Fetal Cardiac Dimensions, Volumes, Ventricular Function and Left Ventricular Longitudinal Strain Using Doppler Ultrasound Gated Cardiac Magnetic Resonance Imaging in Healthy Third Trimester Fetuses. Journal of Magnetic Resonance Imaging. 2024. doi:10.1002/jmri.29077

BibTeX
@article{Minocha2024,
  author = {Minocha, Prashant K and Englund, Erin K and Friesen, Richard M and Fujiwara, Takashi and Smith, Sarah A and Meyers, Mariana L and Browne, Lorna P and Barker, Alex J},
  title = {Reference Values for Fetal Cardiac Dimensions, Volumes, Ventricular Function and Left Ventricular Longitudinal Strain Using Doppler Ultrasound Gated Cardiac Magnetic Resonance Imaging in Healthy Third Trimester Fetuses},
  journal = {Journal of Magnetic Resonance Imaging},
  year = {2024},
  doi = {10.1002/jmri.29077}
}