The accuracy of computerized biophotogrammetry in diagnosing changes in the cervical spine and its reliability for the cervical lordosis angle
Journal of Back and Musculoskeletal Rehabilitation · 04.01.2023 · 36 (1) · 187-198
DOI: 10.3233/bmr-210375 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Back and Musculoskeletal Rehabilitation, erschienen am 04.01.2023. Verfasst von Priscila Maria Nascimento Martins de Albuquerque und 8 weiteren Autor:innen. Hauptthemen laut MEDLINE: Lordosis. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 38 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Accuracy studies of biophotogrammetry protocols require standardization similar to radiography. OBJECTIVE: To estimate the diagnostic accuracy of a biophotogrammetric assessment protocol for cervical hyperlordosis, compared to radiography, and its intra- and inter-examiner reliability for measuring the cervical lordosis angle. METHODS: A study of diagnostic accuracy in women complaining of cervical pain. Two photos were taken using the CorelDraw biophotogrammetric protocol and one radiograph using the Cobb C1-C7 method. The Intra- and Inter-examiner reliability was calculated using the Kappa index and the intraclass correlation coefficient (ICC). The Bland-Altman plot and the ROC curve were presented. RESULTS: The sample consisted of 19 women. The accuracy of biophotogrammetry was 94.73% and the reliability between biophotogrammetry and radiography presented an ICC of 0.84 and a Kappa of 0.87. The excellent intra (ICC = 0.94) and inter-examiner (ICC = 0.86) reliability of the biophotogrammetry was confirmed. The area under the ROC curve was 93.5%. The Bland-Altman plot indicated differences between the two instruments close to the mean (1.5∘). CONCLUSION: The biophotogrammetric protocol proved to be accurate in diagnosing cervical hyperlordosis, with excellent reliability between the biophotogrammetric and radiographic assessments. It also demonstrated excellent intra- and inter-examiner reliability in measuring the cervical lordosis angle.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Zitieren
APA
de Albuquerque, P. M. N. M., de Oliveira, D. A., do Nascimento Alves, L. I., da Silva Alves Gomes, V. M., Bezerra, L. M. R., de Souza Melo, T. M., de Alencar, G. G., da Silva Tenório, A., & de Siqueira, G. R. (2023). The accuracy of computerized biophotogrammetry in diagnosing changes in the cervical spine and its reliability for the cervical lordosis angle. Journal of Back and Musculoskeletal Rehabilitation, 36(1), 187-198. https://doi.org/10.3233/bmr-210375
Vancouver
de Albuquerque PMNM, de Oliveira DA, do Nascimento Alves LI, da Silva Alves Gomes VM, Bezerra LMR, de Souza Melo TM, et al. The accuracy of computerized biophotogrammetry in diagnosing changes in the cervical spine and its reliability for the cervical lordosis angle. Journal of Back and Musculoskeletal Rehabilitation. 2023;36(1):187-198. doi:10.3233/bmr-210375
BibTeX
@article{deAlbuquerque2023,
author = {de Albuquerque, Priscila Maria Nascimento Martins and de Oliveira, Daniella Araújo and do Nascimento Alves, Laura Izabel and da Silva Alves Gomes, Vanessa Maria and Bezerra, Laylla Marjorye Rebouças and de Souza Melo, Thania Maion and de Alencar, Geisa Guimarães and da Silva Tenório, Angélica and de Siqueira, Gisela Rocha},
title = {The accuracy of computerized biophotogrammetry in diagnosing changes in the cervical spine and its reliability for the cervical lordosis angle},
journal = {Journal of Back and Musculoskeletal Rehabilitation},
year = {2023},
volume = {36},
number = {1},
pages = {187--198},
doi = {10.3233/bmr-210375}
}
EUVIMED