Unveiling and Validating a Modified Method to Assess Cervical Sagittal Alignment as an Effective Substitute for Conventional C2-7 Cobb Angle
Clinics in Orthopedic Surgery · 2025
DOI: 10.4055/cios24186 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Clinics in Orthopedic Surgery, 2025. Verfasst von Wenpeng Li und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurosurgery, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China. Hauptthemen laut MEDLINE: Cervical Vertebrae, Lordosis. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Background
Developing and validating a modified parameter, the SYS-G angle (the angle between the lower endplate of the C2 and the upper endplate of C7 vertebrae), as a feasible substitute for the C2-C7 Cobb method in assessing cervical sagittal alignment and exploring its reference range through a large-scale retrospective study.
Methods
The visibility of the C6, C7 upper, and C7 lower endplates was graded and compared. Baseline data such as height, weight, body mass index (BMI), age, and sex were analyzed for their impact on the visibility of the C7 lower endplate. Values of C2-6 Cobb angle, SYS-G angle, and C2-7 Cobb angle were measured. The intra- and interobserver reliability, differences, and efficacy of evaluation on cervical lordosis of the parameters were compared, and the correlations among the parameters were analyzed. Furthermore, reference ranges for the SYS-G angle were established based on lateral cervical spine x-rays of 825 asymptomatic Chinese adults across different age groups and sexes.
Results
The visibility of the C7 lower endplates was significantly reduced compared to the C6 lower and C7 upper endplates. Age, weight, BMI, and male sex were identified as factors negatively influencing the visibility of the C7 lower endplate. Both intraobserver and interobserver reliability demonstrated excellence for all tested parameters. The linear regression model unveiled a stronger association of the SYS-G angle with the C2-7 Cobb angle compared to the C2-6 Cobb angle. Furthermore, the SYS-G angle exhibited excellent efficacy in evaluating cervical lordosis. Age displayed a positive correlation with the SYS-G angle, and across every age bracket from 20 to 69 years, men exhibited a higher mean SYS-G angle compared to women.
Conclusions
The visibility of the C7 lower endplate diminishes with increasing age, weight, BMI, and male sex. In cases where the C7 lower endplate is unclear, the SYS-G angle emerges as a reliable method for estimating cervical sagittal morphology. Reference ranges for the SYS-G angle were established across various age groups and sexes among asymptomatic Chinese adults, offering a valuable resource to guide therapeutic interventions for cervical spine disorders and deformities.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Neurosurgery, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China.
- Department of Orthopedics, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China.
ORCID-Profile: Wenpeng Li, Qiwei Wang, Qiancheng Zhao, Ziliang Zeng, Xumin Hu, Xin Lv, Liangbin Gao
Zitieren
APA
Li, W., Wang, Q., Zhao, Q., Zeng, Z., Hu, X., Lv, X., & Gao, L. (2025). Unveiling and Validating a Modified Method to Assess Cervical Sagittal Alignment as an Effective Substitute for Conventional C2-7 Cobb Angle. Clinics in Orthopedic Surgery. https://doi.org/10.4055/cios24186
Vancouver
Li W, Wang Q, Zhao Q, Zeng Z, Hu X, Lv X, et al. Unveiling and Validating a Modified Method to Assess Cervical Sagittal Alignment as an Effective Substitute for Conventional C2-7 Cobb Angle. Clinics in Orthopedic Surgery. 2025. doi:10.4055/cios24186
BibTeX
@article{Li2025,
author = {Li, Wenpeng and Wang, Qiwei and Zhao, Qiancheng and Zeng, Ziliang and Hu, Xumin and Lv, Xin and Gao, Liangbin},
title = {Unveiling and Validating a Modified Method to Assess Cervical Sagittal Alignment as an Effective Substitute for Conventional C2-7 Cobb Angle},
journal = {Clinics in Orthopedic Surgery},
year = {2025},
doi = {10.4055/cios24186}
}
EUVIMED