EUVIMEDSkopri EUVIMED
Open access · CC BY 4.0

Reduced fibrous capsule elastic fibers from biologic ECM-enveloped CIEDs in minipigs, supported with a novel compression mechanics model

Roche C de Guzman, Allison S Meer, Aidan A Mathews, Atara R Israel, Michael T Moses, Clarence M Sams, Daniel B Deegan

Bio-Medical Materials and Engineering · 2023

DOI: 10.3233/bme-221488 ↗

At a glance

Journal article in Bio-Medical Materials and Engineering, 2023. Written by Roche C de Guzman and 6 co-authors. Institution: Bioengineering Program, Department of Engineering, Hofstra University, Hempstead, NY, USA. Major MEDLINE topics: Elastin, Biological Products. Cited 8 times so far (Crossref); 56 references. The full text is freely available (open access, CC BY 4.0).

AstrattSubjectsDettalji biblijografiċiCiteRelated studies

Abstract (original language)

BACKGROUND: Fibrous capsules (Fb) in response to cardiovascular implantable electronic devices (CIEDs), including a pacemaker (P) system, can produce patient discomfort and difficulties in revision surgery due partially to their increased compressive strength, previously linked to elevated tissue fibers. OBJECTIVE: A preliminary study to quantify structural proteins, determine if biologic extracellular matrix-enveloped CIEDs (PECM) caused differential Fb properties, and to implement a realistic mechanical model. METHODS: Retrieved Fb (-P and -PECM) from minipigs were subjected to biomechanical (shear oscillation and uniaxial compression) and histological (collagen I and elastin) analyses. RESULTS: Fb-PECM showed significant decreases compared to Fb-P in: low strain-loss modulus (390 vs. 541 Pa) across angular frequencies, high strain-compressive elastic modulus (1043 vs. 2042 kPa), and elastic fiber content (1.92 vs. 3.15 μg/mg tissue). Decreases in elastin were particularly noted closer to the implant’s surface (Fb-PECM = 71% vs. Fb-P = 143% relative to dermal elastin at mid-tangential sections) and verified with a solid mechanics hyperelasticity with direction-dependent fiber viscoelasticity compression simulation (r2 ≥ 98.9%). CONCLUSIONS: The biologic envelope composed of decellularized porcine small intestine submucosa ECM for CIEDs promoted fibrous tissues with less elastic fibers. Novel compression modeling analyses directly correlated this singular reduction to more desirable subcutaneous tissue mechanics.

Subjects

MeSH terms (MEDLINE)

ElastinBiological ProductsSwineAnimalsSwine, MiniatureElastic TissueExtracellular MatrixElastic ModulusBiomechanical Phenomena

Author keywords

3D distributionCOMSOL multiphysics hyperelastic simulationMinipig studybiologic envelopecardiovascular implantable electronic devicescompression biomechanicsdecellularized tissue ECMelastin and elastic fibersfibrous tissue encapsulationforeign body reactionoscillation rheologypacemaker

Substances

ElastinBiological Products

Authors and institutions

  • Bioengineering Program, Department of Engineering, Hofstra University, Hempstead, NY, USA.
  • Department of Biology, Hofstra University, Hempstead, NY, USA.
  • Aziyo Biologics, Inc., Silver Spring, MD, USA.

Cite

APA

de Guzman, R. C., Meer, A. S., Mathews, A. A., Israel, A. R., Moses, M. T., Sams, C. M., & Deegan, D. B. (2023). Reduced fibrous capsule elastic fibers from biologic ECM-enveloped CIEDs in minipigs, supported with a novel compression mechanics model. Bio-Medical Materials and Engineering. https://doi.org/10.3233/bme-221488

Vancouver

de Guzman RC, Meer AS, Mathews AA, Israel AR, Moses MT, Sams CM, et al. Reduced fibrous capsule elastic fibers from biologic ECM-enveloped CIEDs in minipigs, supported with a novel compression mechanics model. Bio-Medical Materials and Engineering. 2023. doi:10.3233/bme-221488

BibTeX
@article{deGuzman2023,
  author = {de Guzman, Roche C and Meer, Allison S and Mathews, Aidan A and Israel, Atara R and Moses, Michael T and Sams, Clarence M and Deegan, Daniel B},
  title = {Reduced fibrous capsule elastic fibers from biologic ECM-enveloped CIEDs in minipigs, supported with a novel compression mechanics model},
  journal = {Bio-Medical Materials and Engineering},
  year = {2023},
  doi = {10.3233/bme-221488}
}