Reduced fibrous capsule elastic fibers from biologic ECM-enveloped CIEDs in minipigs, supported with a novel compression mechanics model
Bio-Medical Materials and Engineering · 2023
DOI: 10.3233/bme-221488 ↗Kurz gefasst
Fachartikel in der Zeitschrift Bio-Medical Materials and Engineering, 2023. Verfasst von Roche C de Guzman und 6 weiteren Autor:innen. Beteiligte Einrichtung: Bioengineering Program, Department of Engineering, Hofstra University, Hempstead, NY, USA. Hauptthemen laut MEDLINE: Elastin, Biological Products. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 56 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
BACKGROUND: Fibrous capsules (Fb) in response to cardiovascular implantable electronic devices (CIEDs), including a pacemaker (P) system, can produce patient discomfort and difficulties in revision surgery due partially to their increased compressive strength, previously linked to elevated tissue fibers. OBJECTIVE: A preliminary study to quantify structural proteins, determine if biologic extracellular matrix-enveloped CIEDs (PECM) caused differential Fb properties, and to implement a realistic mechanical model. METHODS: Retrieved Fb (-P and -PECM) from minipigs were subjected to biomechanical (shear oscillation and uniaxial compression) and histological (collagen I and elastin) analyses. RESULTS: Fb-PECM showed significant decreases compared to Fb-P in: low strain-loss modulus (390 vs. 541 Pa) across angular frequencies, high strain-compressive elastic modulus (1043 vs. 2042 kPa), and elastic fiber content (1.92 vs. 3.15 μg/mg tissue). Decreases in elastin were particularly noted closer to the implant’s surface (Fb-PECM = 71% vs. Fb-P = 143% relative to dermal elastin at mid-tangential sections) and verified with a solid mechanics hyperelasticity with direction-dependent fiber viscoelasticity compression simulation (r2 ≥ 98.9%). CONCLUSIONS: The biologic envelope composed of decellularized porcine small intestine submucosa ECM for CIEDs promoted fibrous tissues with less elastic fibers. Novel compression modeling analyses directly correlated this singular reduction to more desirable subcutaneous tissue mechanics.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Bioengineering Program, Department of Engineering, Hofstra University, Hempstead, NY, USA.
- Department of Biology, Hofstra University, Hempstead, NY, USA.
- Aziyo Biologics, Inc., Silver Spring, MD, USA.
Zitieren
APA
de Guzman, R. C., Meer, A. S., Mathews, A. A., Israel, A. R., Moses, M. T., Sams, C. M., & Deegan, D. B. (2023). Reduced fibrous capsule elastic fibers from biologic ECM-enveloped CIEDs in minipigs, supported with a novel compression mechanics model. Bio-Medical Materials and Engineering. https://doi.org/10.3233/bme-221488
Vancouver
de Guzman RC, Meer AS, Mathews AA, Israel AR, Moses MT, Sams CM, et al. Reduced fibrous capsule elastic fibers from biologic ECM-enveloped CIEDs in minipigs, supported with a novel compression mechanics model. Bio-Medical Materials and Engineering. 2023. doi:10.3233/bme-221488