Analysis of shear stress related hemolysis in a ventricular assist device

Mohamed Bounouib, Hind Benakrach, Mourad Taha-Janan, Wajih Maazouzi

Bio-Medical Materials and Engineering · 2023

DOI: 10.3233/bme-221401 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Bio-Medical Materials and Engineering, 2023. Verfasst von Mohamed Bounouib und 3 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory of Applied Mechanics and Technologies, ENSAM, Mohammed V University, Rabat, Morocco. Hauptthemen laut MEDLINE: Heart-Assist Devices. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 23 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Implantable devices such as ventricular assist devices provide appropriate treatment for patients with advanced heart failure. Unfortunately, these devices still have many problems, particularly related to blood damage. OBJECTIVE: The aim of this research is to examine two new ventricular assist devices in terms of induced shear stress, exposure time, and induced hemolysis. METHOD: Reverse engineering was used on multiple axial flow ventricular assist devices to collect all the details related to the designs (diameters, lengths, blade angles…), which were used to build two prototypes: Model A and Model B. RESULTS: The obtained results were close to a large extent, except for static pressure rise, where the difference was clear. CONCLUSION: Compared with what has been published in other studies, the overall performance of both models was excellent.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart-Assist DevicesHumansHemolysisStress, MechanicalHemodynamicsModels, Cardiovascular

Stichwörter der Autor:innen

CFDComputational fluid dynamicsVADhemodynamicshemolysishemolysis indexshear stress

Autor:innen und Institutionen

  • Laboratory of Applied Mechanics and Technologies, ENSAM, Mohammed V University, Rabat, Morocco.
  • Industrial and Health Science and Technology Research Center (STIS), ENSAM, Mohammed V University, Rabat, Morocco.

Zitieren

APA

Bounouib, M., Benakrach, H., Taha-Janan, M., & Maazouzi, W. (2023). Analysis of shear stress related hemolysis in a ventricular assist device. Bio-Medical Materials and Engineering. https://doi.org/10.3233/bme-221401

Vancouver

Bounouib M, Benakrach H, Taha-Janan M, Maazouzi W. Analysis of shear stress related hemolysis in a ventricular assist device. Bio-Medical Materials and Engineering. 2023. doi:10.3233/bme-221401

BibTeX
@article{Bounouib2023,
  author = {Bounouib, Mohamed and Benakrach, Hind and Taha-Janan, Mourad and Maazouzi, Wajih},
  title = {Analysis of shear stress related hemolysis in a ventricular assist device},
  journal = {Bio-Medical Materials and Engineering},
  year = {2023},
  doi = {10.3233/bme-221401}
}
Kostenlos starten →