EUVIMEDObjevte EUVIMED
Crossref

An in vivo preclinical study assessing biocompatibility of Pd-based bulk metallic glass

Lukasz Witek, Vasudev Vivekanand Nayak, Ricardo Rodriguez Colon, Andrea Torroni, Marios D Demetriou, Paulo G Coelho

Bio-Medical Materials and Engineering · 2023

DOI: 10.3233/bme-221392 ↗

At a glance

Journal article in Bio-Medical Materials and Engineering, 2023. Written by Lukasz Witek and 5 co-authors. Institution: Biomaterials Division, Department of Molecular Pathobiology, New York University College of Dentistry, New York, NY, USA. Major MEDLINE topics: Alloys, Dental Implants. Cited 1 times so far (Crossref); 33 references.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

BACKGROUND: The bulk metallic glass (BMG), Pd79Ag3.5P6Si9.5Ge2, has a high fracture toughness and has been found to accommodate post-yield stress, unlike most other BMG. Moreover, due to its greater noble gas composition it has a intrinsic corrosion resistance, ideal for dental and orthopedic implants. OBJECTIVE: This present study aimed to evaluate the in vivo application of Pd79Ag3.5P6Si9.5Ge2 in a large translational sheep model to assess its efficacy to be utilized as an endosteal device. METHODS: Twelve implants in the form of cylindrical rods (3 mm in diameter) were produced through rapid quenching. Each sheep (n = 12) received one osteotomy in the mandibular region using rotary instrumentation, which was filled with Pd79Ag3.5P6Si9.5Ge2. After 6- and 24-weeks the animals were euthanized, and samples collected en bloc to conduct histomorphometric analysis. The degree of osseointegration were assessed through bone-to-implant contact (BIC). RESULTS: All samples revealed favorable BIC along with with fibrous connective tissue layers at both 6- and 24-weeks. Bone along with interfacial remodeling was observed in proximity with the metallic glass surface at 6 weeks with higher degrees of bone organization being observed at the later healing time, 24 weeks. CONCLUSIONS: The synthesized BMG, given its unique combination of toughness and strength, revealed potential to serve as an alternative to commonly used Ti alloys.

Subjects

MeSH terms (MEDLINE)

AlloysDental ImplantsAnimalsSheepOsseointegrationProstheses and ImplantsTitaniumSurface PropertiesGlass

Author keywords

Bulk metallic glassin vivomedical implants

Substances

AlloysDental ImplantsTitanium

Authors and institutions

  • Biomaterials Division, Department of Molecular Pathobiology, New York University College of Dentistry, New York, NY, USA.
  • Department of Biomedical Engineering, New York University Tandon School of Engineering, Brooklyn, NY, USA.
  • Department of Mechanical and Aerospace Engineering, New York University Tandon School of Engineering, Brooklyn, NY, USA.
  • Icahn School of Medicine at Mount Sinai, New York, NY, USA.
  • Hansjörg Wyss Department of Plastic Surgery, New York University School of Medicine, New York, NY, USA.
  • Department of Materials Science, California Institute of Technology, Pasadena, CA, USA.

Cite

APA

Witek, L., Vivekanand Nayak, V., Rodriguez Colon, R., Torroni, A., Demetriou, M. D., & Coelho, P. G. (2023). An in vivo preclinical study assessing biocompatibility of Pd-based bulk metallic glass. Bio-Medical Materials and Engineering. https://doi.org/10.3233/bme-221392

Vancouver

Witek L, Vivekanand Nayak V, Rodriguez Colon R, Torroni A, Demetriou MD, Coelho PG. An in vivo preclinical study assessing biocompatibility of Pd-based bulk metallic glass. Bio-Medical Materials and Engineering. 2023. doi:10.3233/bme-221392

BibTeX
@article{Witek2023,
  author = {Witek, Lukasz and Vivekanand Nayak, Vasudev and Rodriguez Colon, Ricardo and Torroni, Andrea and Demetriou, Marios D and Coelho, Paulo G},
  title = {An in vivo preclinical study assessing biocompatibility of Pd-based bulk metallic glass},
  journal = {Bio-Medical Materials and Engineering},
  year = {2023},
  doi = {10.3233/bme-221392}
}
Start for free →