Fachartikel in der Zeitschrift Bio-Medical Materials and Engineering, 2023. Verfasst von Lukasz Witek und 5 weiteren Autor:innen. Beteiligte Einrichtung: Biomaterials Division, Department of Molecular Pathobiology, New York University College of Dentistry, New York, NY, USA. Hauptthemen laut MEDLINE: Alloys, Dental Implants. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 33 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: The bulk metallic glass (BMG), Pd79Ag3.5P6Si9.5Ge2, has a high fracture toughness and has been found to accommodate post-yield stress, unlike most other BMG. Moreover, due to its greater noble gas composition it has a intrinsic corrosion resistance, ideal for dental and orthopedic implants. OBJECTIVE: This present study aimed to evaluate the in vivo application of Pd79Ag3.5P6Si9.5Ge2 in a large translational sheep model to assess its efficacy to be utilized as an endosteal device. METHODS: Twelve implants in the form of cylindrical rods (3 mm in diameter) were produced through rapid quenching. Each sheep (n = 12) received one osteotomy in the mandibular region using rotary instrumentation, which was filled with Pd79Ag3.5P6Si9.5Ge2. After 6- and 24-weeks the animals were euthanized, and samples collected en bloc to conduct histomorphometric analysis. The degree of osseointegration were assessed through bone-to-implant contact (BIC). RESULTS: All samples revealed favorable BIC along with with fibrous connective tissue layers at both 6- and 24-weeks. Bone along with interfacial remodeling was observed in proximity with the metallic glass surface at 6 weeks with higher degrees of bone organization being observed at the later healing time, 24 weeks. CONCLUSIONS: The synthesized BMG, given its unique combination of toughness and strength, revealed potential to serve as an alternative to commonly used Ti alloys.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Biomaterials Division, Department of Molecular Pathobiology, New York University College of Dentistry, New York, NY, USA.
- Department of Biomedical Engineering, New York University Tandon School of Engineering, Brooklyn, NY, USA.
- Department of Mechanical and Aerospace Engineering, New York University Tandon School of Engineering, Brooklyn, NY, USA.
- Icahn School of Medicine at Mount Sinai, New York, NY, USA.
- Hansjörg Wyss Department of Plastic Surgery, New York University School of Medicine, New York, NY, USA.
- Department of Materials Science, California Institute of Technology, Pasadena, CA, USA.
Zitieren
APA
Witek, L., Vivekanand Nayak, V., Rodriguez Colon, R., Torroni, A., Demetriou, M. D., & Coelho, P. G. (2023). An in vivo preclinical study assessing biocompatibility of Pd-based bulk metallic glass. Bio-Medical Materials and Engineering. https://doi.org/10.3233/bme-221392
Vancouver
Witek L, Vivekanand Nayak V, Rodriguez Colon R, Torroni A, Demetriou MD, Coelho PG. An in vivo preclinical study assessing biocompatibility of Pd-based bulk metallic glass. Bio-Medical Materials and Engineering. 2023. doi:10.3233/bme-221392
BibTeX
@article{Witek2023,
author = {Witek, Lukasz and Vivekanand Nayak, Vasudev and Rodriguez Colon, Ricardo and Torroni, Andrea and Demetriou, Marios D and Coelho, Paulo G},
title = {An in vivo preclinical study assessing biocompatibility of Pd-based bulk metallic glass},
journal = {Bio-Medical Materials and Engineering},
year = {2023},
doi = {10.3233/bme-221392}
}
EUVIMED