EUVIMEDEUVIMED entdecken
Crossref

Normal coronal kinematics of dynamic alignment and bony positions relative to the ground in three-dimensional motion analysis during gait: A preliminary study

Yasuyuki Tomiyama, Tomoharu Mochizuki, Osamu Tanifuji, Katsutoshi Nishino, Masaei Tanaka, Go Omori, Noriaki Yamamoto, Hiroshi Koga, Yoshio Koga, Hiroyuki Kawashima

Bio-Medical Materials and Engineering · 11.01.2023 · 34 (1) · 37-49

DOI: 10.3233/bme-211383 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Bio-Medical Materials and Engineering, erschienen am 11.01.2023. Verfasst von Yasuyuki Tomiyama und 9 weiteren Autor:innen. Beteiligte Einrichtung: Division of Orthopedic Surgery, Department of Regenerative and Transplant Medicine, Niigata University Graduate School of Medical and Dental Science,…. Hauptthemen laut MEDLINE: Gait, Tibia. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 28 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: During gait, healthy knee coronal kinematics of each bony axis and lower extremity alignment are important because they could be useful as reference data for several surgeries and provide clarification of the etiology of diseases around the knee in healthy participants; however, it remains unknown. OBJECTIVE: The objective of this study was to clarify the kinematics of lower extremity alignment and the bony axes relative to the ground during gait, focused on the coronal plane, in healthy individuals by applying our unique three-dimensional (3D) motion analysis. METHODS: The study included 21 healthy individuals, including 9 healthy females and 12 healthy males with an average age of 36 ± 17 years. Knee kinematics were calculated in a gait analysis by combining the data from a motion-capture system and a 3D lower-extremity alignment assessment system on biplanar long-leg radiographs by using a 3D-2D registration technique. The main kinematic parameters were the dynamic position change relative to the ground, applying the femoral anatomical axis (FAA), tibial anatomical axis (TAA), and dynamic alignment in the coronal plane during the stance phase of gait. RESULTS: The average changes in FAA, TAA, and dynamic varus alignment were 3.7° ± 1.2°, 3.5° ± 0.8°, and 3.0° ± 1.2°, respectively. The TAA tilted laterally during the loading response and a plateau area appeared afterwards; the FAA gradually inclined laterally until the terminal stance phase, and the dynamic alignment showed varus angular change during the loading response. CONCLUSIONS: The tibia and femur were found to change approximately 2–5° of the position of the bony axes relative to the ground. In terms of clinical relevance, our findings can be used to clarify the etiology of diseases around the knee joint and as reference data for surgeries.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

GaitTibiaMaleFemaleHumansYoung AdultAdultMiddle AgedBiomechanical PhenomenaKnee JointFemurRange of Motion, Articular

Stichwörter der Autor:innen

Normal knee kinematicsbony axisdynamic alignmentgait analysis

Autor:innen und Institutionen

  • Division of Orthopedic Surgery, Department of Regenerative and Transplant Medicine, Niigata University Graduate School of Medical and Dental Science, Niigata, Japan.
  • Department of Orthopaedic Surgery, Niigata Rehabilitation Hospital, Niitaga, Japan.
  • Niigata Institute for Health and Sports Medicine, Niigata, Japan.
  • Department of Health and Sports, Faculty of Health Sciences, Niigata University of Health and Welfare, Niigata, Japan.
  • Division of Musculoskeletal Science for Frailty, Niigata University Graduate School of Medical and Dental Sciences, Niigata, Japan.
  • Department of Orthopaedic Surgery, Nioji Onsen Hospital, Niigata, Japan.

Zitieren

APA

Tomiyama, Y., Mochizuki, T., Tanifuji, O., Nishino, K., Tanaka, M., Omori, G., Yamamoto, N., Koga, H., Koga, Y., & Kawashima, H. (2023). Normal coronal kinematics of dynamic alignment and bony positions relative to the ground in three-dimensional motion analysis during gait: A preliminary study. Bio-Medical Materials and Engineering, 34(1), 37-49. https://doi.org/10.3233/bme-211383

Vancouver

Tomiyama Y, Mochizuki T, Tanifuji O, Nishino K, Tanaka M, Omori G, et al. Normal coronal kinematics of dynamic alignment and bony positions relative to the ground in three-dimensional motion analysis during gait: A preliminary study. Bio-Medical Materials and Engineering. 2023;34(1):37-49. doi:10.3233/bme-211383

BibTeX
@article{Tomiyama2023,
  author = {Tomiyama, Yasuyuki and Mochizuki, Tomoharu and Tanifuji, Osamu and Nishino, Katsutoshi and Tanaka, Masaei and Omori, Go and Yamamoto, Noriaki and Koga, Hiroshi and Koga, Yoshio and Kawashima, Hiroyuki},
  title = {Normal coronal kinematics of dynamic alignment and bony positions relative to the ground in three-dimensional motion analysis during gait: A preliminary study},
  journal = {Bio-Medical Materials and Engineering},
  year = {2023},
  volume = {34},
  number = {1},
  pages = {37--49},
  doi = {10.3233/bme-211383}
}
Kostenlos starten →