EUVIMEDAtrasti EUVIMED
Crossref

Patient specific 3-d modeling of blood flow in a multi-stenosed left coronary artery

Sarfaraz Kamangar, Irfan Anjum Badruddin, N Ameer Ahamad, Manzoor Elahi M Soudagar, Kalimuthu Govindaraju, N Nik-Ghazali, N J Salman Ahmed, T M Yunus Khan

Bio-Medical Materials and Engineering · 2017-05-19 · 28 (3) · 257-266

DOI: 10.3233/bme-171672 ↗

At a glance

Journal article in Bio-Medical Materials and Engineering, published on 2017-05-19. Written by Sarfaraz Kamangar and 7 co-authors. Institution: Department of Mechanical Engineering, University of Malaya, Kuala Lumpur 50603, Malaysia. Major MEDLINE topics: Models, Cardiovascular, Patient-Specific Modeling. Cited 13 times so far (Crossref); 27 references.

SantraukaSubjectsBibliografiniai duomenysCiteRelated studies

Abstract (original language)

The current study investigates the effect of multi stenosis on the hemodynamic parameters such as wall pressure, velocity and wall shear stress in the realistic left coronary artery. Patients CT scan image data of normal and diseased left coronary artery was chosen for the reconstruction of 3D coronary artery models. The diseased 3D model of left coronary artery shows a narrowing of more than 70% and 80% of area stenosis (AS) at the left main stem (LMS) and left circumflex (LCX) respectively. The results show that the decrease in pressure was found downstream to the stenosis as compared to the coronary artery without stenosis. The maximum pressure drop was noted across the 80% AS at the left circumflex branch. The recirculation zone was also observed immediate to the stenosis and highest wall shear stress was found across the 80% area stenosis. Our analysis provides an insight into the distribution of wall shear stress and pressure drop, thus improving our understanding on the hemodynamics in realistic coronary artery.

Subjects

MeSH terms (MEDLINE)

Models, CardiovascularPatient-Specific ModelingBlood Flow VelocityCoronary CirculationCoronary StenosisCoronary VesselsHemodynamicsHumans

Author keywords

CFDCoronary arterycomputer tomographynon-Newtonian flowstenosis

Authors and institutions

  • Department of Mechanical Engineering, University of Malaya, Kuala Lumpur 50603, Malaysia.
  • Mathematics Department, Faculty of Science, University of Tabuk, Saudi Arabia.
  • Department of Mechanical Engineering, Jain College of Engineering, Belagavi, 590014, India.
  • Department of Mechanical and Industrial Engineering, Mekelle University, Mekelle, Ethiopia.
  • Department of Mechanical and Industrial Engineering, Sultan Qaboos University, Al Khoud, Muscat, 123, Oman.

Cite

APA

Kamangar, S., Badruddin, I. A., Ameer Ahamad, N., Soudagar, M. E. M., Govindaraju, K., Nik-Ghazali, N., Salman Ahmed, N. J., & Yunus Khan, T. M. (2017). Patient specific 3-d modeling of blood flow in a multi-stenosed left coronary artery. Bio-Medical Materials and Engineering, 28(3), 257-266. https://doi.org/10.3233/bme-171672

Vancouver

Kamangar S, Badruddin IA, Ameer Ahamad N, Soudagar MEM, Govindaraju K, Nik-Ghazali N, et al. Patient specific 3-d modeling of blood flow in a multi-stenosed left coronary artery. Bio-Medical Materials and Engineering. 2017;28(3):257-266. doi:10.3233/bme-171672

BibTeX
@article{Kamangar2017,
  author = {Kamangar, Sarfaraz and Badruddin, Irfan Anjum and Ameer Ahamad, N and Soudagar, Manzoor Elahi M and Govindaraju, Kalimuthu and Nik-Ghazali, N and Salman Ahmed, N J and Yunus Khan, T M},
  title = {Patient specific 3-d modeling of blood flow in a multi-stenosed left coronary artery},
  journal = {Bio-Medical Materials and Engineering},
  year = {2017},
  volume = {28},
  number = {3},
  pages = {257--266},
  doi = {10.3233/bme-171672}
}
Start for free →