EUVIMEDEUVIMED entdecken
Crossref

The effects of non-Newtonian blood modeling and pulsatility on hemodynamics in the food and drug administration’s benchmark nozzle model

Bryan C Good

Biorheology: The Official Journal of the International Society of Biorheology · 2023

DOI: 10.3233/bir-201019 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biorheology: The Official Journal of the International Society of Biorheology, 2023. Verfasst von Bryan C Good. Beteiligte Einrichtung: Department of Mechanical, Aerospace, and Biomedical Engineering, University of Tennessee, Knoxville, TN, USA. Hauptthemen laut MEDLINE: Hemodynamics. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 36 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Computational fluid dynamics (CFD) is an important tool for predicting cardiovascular device performance. The FDA developed a benchmark nozzle model in which experimental and CFD data were compared, however, the studies were limited by steady flows and Newtonian models. OBJECTIVE: Newtonian and non-Newtonian blood models will be compared under steady and pulsatile flows to evaluate their influence on hemodynamics in the FDA nozzle. METHODS: CFD simulations were validated against the FDA data for steady flow with a Newtonian model. Further simulations were performed using Newtonian and non-Newtonian models under both steady and pulsatile flows. RESULTS: CFD results were within the experimental standard deviations at nearly all locations and Reynolds numbers. The model differences were most evident at Re = 500, in the recirculation regions, and during diastole. The non-Newtonian model predicted blunter upstream velocity profiles, higher velocities in the throat, and differences in the recirculation flow patterns. The non-Newtonian model also predicted a greater pressure drop at Re = 500 with minimal differences observed at higher Reynolds numbers. CONCLUSIONS: An improved modeling framework and validation procedure were used to further investigate hemodynamics in geometries relevant to cardiovascular devices and found that accounting for blood’s non-Newtonian and pulsatile behavior can lead to large differences in predictions in hemodynamic parameters.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

HemodynamicsUnited StatesPharmaceutical PreparationsUnited States Food and Drug AdministrationPulsatile FlowModels, CardiovascularBlood Flow VelocityComputer SimulationStress, Mechanical

Stichwörter der Autor:innen

FDAbenchmarkcomputational fluid dynamicsnon-Newtonianpulsatility

Substanzen

Pharmaceutical Preparations

Autor:innen und Institutionen

  • Department of Mechanical, Aerospace, and Biomedical Engineering, University of Tennessee, Knoxville, TN, USA.

Zitieren

APA

Good, B. C. (2023). The effects of non-Newtonian blood modeling and pulsatility on hemodynamics in the food and drug administration’s benchmark nozzle model. Biorheology: The Official Journal of the International Society of Biorheology. https://doi.org/10.3233/bir-201019

Vancouver

Good BC. The effects of non-Newtonian blood modeling and pulsatility on hemodynamics in the food and drug administration’s benchmark nozzle model. Biorheology: The Official Journal of the International Society of Biorheology. 2023. doi:10.3233/bir-201019

BibTeX
@article{Good2023,
  author = {Good, Bryan C},
  title = {The effects of non-Newtonian blood modeling and pulsatility on hemodynamics in the food and drug administration’s benchmark nozzle model},
  journal = {Biorheology: The Official Journal of the International Society of Biorheology},
  year = {2023},
  doi = {10.3233/bir-201019}
}
Kostenlos starten →