EUVIMEDOpdag EUVIMED
FallberichtOpen access · CC BY 4.0

Subtotal diaphyseal replacement of the femur with modular mega-endoprosthesis following interprosthetic fracture. A case report

Mohamed Ghanem, Christina Pempe, Andreas Roth

GMS Interdisciplinary Plastic and Reconstructive Surgery DGPW · 2024-02-09 · 13 (Doc01) · Doc01-Doc01

DOI: 10.3205/iprs000183 ↗

At a glance

Fallbericht in GMS Interdisciplinary Plastic and Reconstructive Surgery DGPW, published on 2024-02-09. Written by Mohamed Ghanem and 2 co-authors. Institution: Department of Orthopedics, Traumatology and Plastic Surgery, University Hospital Leipzig, Germany. The full text is freely available (open access, CC BY 4.0).

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Mega-endoprostheses enable wide management options in the treatment of primary and periprosthetic fracture of the lower extremities. In this study, we report on the use of custom-made subtotal diaphyseal endoprosthetic replacement in treatment of interprosthetic femoral fracture. This procedure is off-label, but in this particular case, it was the safest and most stress-stable treatment option. The implant was delivered within three weeks. The surgical procedure for subtotal replacement of the femoral diaphysis was performed without any intra- or postoperative complication. The duration for the surgical intervention was one hour and 40 minutes. The patient was then mobilized with full weight bearing. At one-year follow-up, the patient did not complain of any pain. The Harris Hip Score HHS improved from 26 to 83 at one-year follow-up, the Western Ontario and McMaster Universities Osteoarthritis Index WOMAC improved from 88 to 16. Mega-endoprostheses enable a wide range of management options in the treatment of primary, peri- and interprosthetic fractures of the lower extremities. In many cases, an individual therapeutic plan is necessary ranging up to the use of custom-made implants.

Subjects

interprosthetic fracturefemoral fracturepatient-specific implantsperiprosthetic fracturestress stabilityHarris hip scoreWOMAC Osteoarthritis Index

Authors and institutions

  • Department of Orthopedics, Traumatology and Plastic Surgery, University Hospital Leipzig, Germany.
  • Department of Physical Therapy and Rehabilitation, University Hospital Leipzig, Germany.

Cite

APA

Ghanem, M., Pempe, C., & Roth, A. (2024). Subtotal diaphyseal replacement of the femur with modular mega-endoprosthesis following interprosthetic fracture. A case report. GMS Interdisciplinary Plastic and Reconstructive Surgery DGPW, 13(Doc01), Doc01-Doc01. https://doi.org/10.3205/iprs000183

Vancouver

Ghanem M, Pempe C, Roth A. Subtotal diaphyseal replacement of the femur with modular mega-endoprosthesis following interprosthetic fracture. A case report. GMS Interdisciplinary Plastic and Reconstructive Surgery DGPW. 2024;13(Doc01):Doc01-Doc01. doi:10.3205/iprs000183

BibTeX
@article{Ghanem2024,
  author = {Ghanem, Mohamed and Pempe, Christina and Roth, Andreas},
  title = {Subtotal diaphyseal replacement of the femur with modular mega-endoprosthesis following interprosthetic fracture. A case report},
  journal = {GMS Interdisciplinary Plastic and Reconstructive Surgery DGPW},
  year = {2024},
  volume = {13},
  number = {Doc01},
  pages = {Doc01--Doc01},
  doi = {10.3205/iprs000183}
}
Start for free →