Subtotal diaphyseal replacement of the femur with modular mega-endoprosthesis following interprosthetic fracture. A case report
GMS Interdisciplinary Plastic and Reconstructive Surgery DGPW · 09.02.2024 · 13 (Doc01) · Doc01-Doc01
DOI: 10.3205/iprs000183 ↗Kurz gefasst
Fallbericht in der Zeitschrift GMS Interdisciplinary Plastic and Reconstructive Surgery DGPW, erschienen am 09.02.2024. Verfasst von Mohamed Ghanem und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedics, Traumatology and Plastic Surgery, University Hospital Leipzig, Germany. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Mega-endoprostheses enable wide management options in the treatment of primary and periprosthetic fracture of the lower extremities. In this study, we report on the use of custom-made subtotal diaphyseal endoprosthetic replacement in treatment of interprosthetic femoral fracture. This procedure is off-label, but in this particular case, it was the safest and most stress-stable treatment option. The implant was delivered within three weeks. The surgical procedure for subtotal replacement of the femoral diaphysis was performed without any intra- or postoperative complication. The duration for the surgical intervention was one hour and 40 minutes. The patient was then mobilized with full weight bearing. At one-year follow-up, the patient did not complain of any pain. The Harris Hip Score HHS improved from 26 to 83 at one-year follow-up, the Western Ontario and McMaster Universities Osteoarthritis Index WOMAC improved from 88 to 16. Mega-endoprostheses enable a wide range of management options in the treatment of primary, peri- and interprosthetic fractures of the lower extremities. In many cases, an individual therapeutic plan is necessary ranging up to the use of custom-made implants.
Schlagwörter
Autor:innen und Institutionen
- Department of Orthopedics, Traumatology and Plastic Surgery, University Hospital Leipzig, Germany.
- Department of Physical Therapy and Rehabilitation, University Hospital Leipzig, Germany.
Zitieren
APA
Ghanem, M., Pempe, C., & Roth, A. (2024). Subtotal diaphyseal replacement of the femur with modular mega-endoprosthesis following interprosthetic fracture. A case report. GMS Interdisciplinary Plastic and Reconstructive Surgery DGPW, 13(Doc01), Doc01-Doc01. https://doi.org/10.3205/iprs000183
Vancouver
Ghanem M, Pempe C, Roth A. Subtotal diaphyseal replacement of the femur with modular mega-endoprosthesis following interprosthetic fracture. A case report. GMS Interdisciplinary Plastic and Reconstructive Surgery DGPW. 2024;13(Doc01):Doc01-Doc01. doi:10.3205/iprs000183
BibTeX
@article{Ghanem2024,
author = {Ghanem, Mohamed and Pempe, Christina and Roth, Andreas},
title = {Subtotal diaphyseal replacement of the femur with modular mega-endoprosthesis following interprosthetic fracture. A case report},
journal = {GMS Interdisciplinary Plastic and Reconstructive Surgery DGPW},
year = {2024},
volume = {13},
number = {Doc01},
pages = {Doc01--Doc01},
doi = {10.3205/iprs000183}
}
EUVIMED